Evidence map›Paper›PMID 34084672›Full record

ArticleCureus2021

Field-in-Field Technique With Intrafractionally Modulated Junction Shifts for Craniospinal Irradiation Planning With Three-Dimensional Conformal Radiation Therapy.

Shabbir Hussain, Abdul Hafeez, Hira Nazim, Rahim Gohar, Muhammad Jawaid Mallick

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 95% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 0 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Shabbir HussainOncology, Ziauddin University, Karachi, PAK.
Abdul HafeezOncology, Ziauddin University, Karachi, PAK.
Hira NazimOncology, Ziauddin University, Karachi, PAK.
Rahim GoharOncology, Aga Khan University Hospital, Nairobi, KEN.
Muhammad Jawaid MallickOncology, Ziauddin University, Karachi, PAK.
Ziauddin University · PKAga Khan University Hospital Nairobi · KE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPlanning craniospinal irradiation (CSI) with ''field-in-field'' (FIF) homogenization technique in combination with daily, intrafractional modulation of the field junctions is needed to avoid spinal cord overdose. Photon-based techniques for CSI may result in dose inhomogeneity within the treatment volume and usually require a weekly manual shift of the field junctions to minimize the possibility of spinal cord overdose. Nowadays, FIF technique is used to feather out the dose inhomogeneity caused by multiple fields. We have started using this technique after acquiring advanced technology machines in recent years. METHODS AND MATERIALS: Sixteen patients treated with three-dimensional conformal radiation therapy (3D-CRT) for CSI were retrospectively chosen for analysis. These patients were treated during 2019-2020. Contouring of planning target volume (PTV) and organs at risk (OAR) was done, and planning was done on Varian Eclipse

resultsWithout FIF technique, the volume receiving 110% of the prescribed dose ranged from 39% to 74% (mean: 62.12%) and volume receiving 120% dose ranged from 8% to 28% (mean: 17.68%), whereas with FIF technique, the thecal sac volume receiving 110% of dose ranged from 2% to 18% (mean: 11%) and volume receiving 120% ranged from 0% to 2%. Volume receiving 100% of the dose was also calculated in both techniques; mean values of this dose range was almost similar in both groups. Later p-value was calculated, and in both dose ranges of thecal sac volume receiving 110% and 120%, the difference in values was statistically significant. Therefore, it proved that plan inhomogeneity improved with FIF technique. This technique provided consistent dose delivery during each fraction of treatment across the junctions. The maximum doses calculated at the junction were higher in the CSI plans without FIF compared to those with FIF technique.

conclusionThis study concludes that better dose homogeneity is achieved with FIF technique as compared to non-FIF technique, and the difference in values was statistically significant.

Indexed as

3d-crtcraniospinal irradiation (csi)field-in-field techniquemedulloblastoma

Identifiers

PMID34084672
PMCPMC8164000
OpenAlexW3157253094

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.