Evidence map›Paper›PMID 34082945›Full record

ArticleMaterials science & engineering. C, Materials for biological applications2021

The role of fretting-frequency on the damage modes of THR modular junction: In-vitro study.

Bartlomiej Radzik, Divya Bijukumar, Kai-Yuan Cheng, Ravindra V Badhe, Mark Barba, Mathew T Mathew

Open access · greenAbstract read
In one paragraph

Article in Materials science & engineering. C, Materials for biological applications, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Bartlomiej RadzikRegenerative Medicine and Disability Research (RMDR) Lab, Department of Biomedical Sciences, UIC College of Medicine at Rockford, IL, United States of America.
Divya BijukumarRegenerative Medicine and Disability Research (RMDR) Lab, Department of Biomedical Sciences, UIC College of Medicine at Rockford, IL, United States of America.
Kai-Yuan ChengDepartment of Civil and Material Engineering, College of Engineering, UIC, Chicago, United States of America.
Ravindra V BadheRegenerative Medicine and Disability Research (RMDR) Lab, Department of Biomedical Sciences, UIC College of Medicine at Rockford, IL, United States of America.
Mark BarbaOrthoIllinois, Rockford, IL, United States of America.
Mathew T MathewRegenerative Medicine and Disability Research (RMDR) Lab, Department of Biomedical Sciences, UIC College of Medicine at Rockford, IL, United States of America; Department of Civil and Material Engineering, College of Engineering, UIC, Chicago, United States of America; Rush University Medical Center, Chicago, IL, United States of America. Electronic address: mtmathew@uic.edu.
University of Illinois Chicago, Rockford campus · USIndo-American Center · US

Funding

Corrosion Induced Hip Implant Failure: Synergistic Interactions of Patient, Material, Design, and Surgical FactorsR01AR070181 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI LUNDBERG, HANNAH JEAN, MATHEW, MATHEW THOPPIL · 2016 to 2020
$2.3M
NIAMS NIH HHS R01 AR070181
6 · The paper itself

Abstract

According to the National Center for Health Statistics, currently, more than 250,000 total hip replacements annually in the US alone, with an estimated increase to 500,000 by the year 2030. The usage of tapered junctions between the femoral neck and head gives the surgeon flexibility in implant assembly. However, these modular junctions are subjected to micro-motion that may cause chemical and fretting-corrosion at the modular junction. Therefore, it is imperative to study these forces to mitigate their effects. The current study aims to understand the effects of fretting-corrosion as a function of fretting frequencies caused by common physical activities in an in-vitro model of hip modular junctions. The fretting system has a tribological contact condition of flat-on-flat, mounted to a load frame. CoCrMo pins were polished and immersed in a synovial fluid-like electrolyte solution (Bovine calf serum 30 g/l). Electrochemical measurements were made using a potentiostat. Samples then undergo 3600 cycles at 50 μm (to simulate gross slips), with a horizontal load at 200 N, and a frequency of 0.5 Hz, 0.7 Hz, 1 Hz, and 1.5 Hz to simulate Sit Down-Stand Up, Stair Climb, Walking, and Jogging, respectively. Worn surfaces were then examined under optical and scanning electron microscopy. The evolution of free potential as a function of time for tested frequencies shows the initial potential drop and stabilized trend in the potential evolution. The sample group at a higher frequency displays a higher tendency of corrosion than a lower frequency; however, the dissipation energy decreases as a function of fretting frequency. Both electrochemical and mechanical responses correlate to the variation in the fretting frequencies. Organometallic complexes were found on the surfaces of the samples that were subjected to a slower frequency of fretting, whereas mechanical grooving was noticed on samples with a faster frequency. Hence, these preliminary studies suggest that implant failure rates may be altered based on fretting-frequencies induced by physical activity. Further studies will be required to verify the findings and explore the potential role of fretting frequency in the damage modes of the modular junction.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisAnimalsCattleCorrosionMaterials TestingProsthesis DesignProsthesis FailureSurface PropertiesFretting-corrosionImplant materialsImplant wearModular junctionTotal hip replacement (THR)

Identifiers

PMID34082945
PMCPMC8457041
OpenAlexW3158766496

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.