Evidence map›Paper›PMID 34082701›Full record

ArticleBMC medical imaging2021

Combined frameless stereotactical biopsy and intraoperative cerebral angiography by 3D-rotational fluoroscopy with intravenous contrast administration: a feasibility study.

Thomas Linsenmann, Andrea Cattaneo, Alexander März, Judith Weiland, Christian Stetter, Robert Nickl, Thomas Westermaier

Open access · goldAbstract read
In one paragraph

Article in BMC medical imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 99% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Thomas LinsenmannDepartment of Neurosurgery, Julius Maximilians University, Josef-Schneider Str. 11, 97080, Würzburg, Germany. Linsenmann_t@ukw.de.ORCID 0000-0001-6763-8680
Andrea CattaneoDepartment of Neurosurgery, Julius Maximilians University, Josef-Schneider Str. 11, 97080, Würzburg, Germany.
Alexander MärzDepartment of Neuroradiology, Julius Maximilians University, Josef-Schneider Str. 11, 97080, Würzburg, Germany.
Judith WeilandDepartment of Neurosurgery, Julius Maximilians University, Josef-Schneider Str. 11, 97080, Würzburg, Germany.
Christian StetterDepartment of Neurosurgery, Julius Maximilians University, Josef-Schneider Str. 11, 97080, Würzburg, Germany.
Robert NicklDepartment of Neurosurgery, Julius Maximilians University, Josef-Schneider Str. 11, 97080, Würzburg, Germany.
Thomas WestermaierDepartment of Neurosurgery, Julius Maximilians University, Josef-Schneider Str. 11, 97080, Würzburg, Germany.
University of Würzburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMobile 3-dimensional fluoroscopes are an integral part of modern neurosurgical operating theatres and can also be used in combination with free available image post processing to depict cerebral vessels. In preparation of stereotactic surgery, preoperative Computed Tomography (CT) may be required for image fusion. Contrast CT may be of further advantage for image fusion as it regards the vessel anatomy in trajectory planning. Time-consuming in-hospital transports are necessary for this purpose. Mobile 3D-fluoroscopes may be used to generate a CT equal preoperative data set without an in-hospital transport. This study was performed to determine the feasibility and image quality of intraoperative 3-dimensional fluoroscopy with intravenous contrast administration in combination with stereotactical procedures.

methods6 patients were included in this feasibility study. After fixation in a radiolucent Mayfield clamp a rotational fluoroscopy scan was performed with 50 mL iodine contrast agent. The image data sets were merged with the existing MRI images at a planning station and visually evaluated by two observer. The operation times were compared between the frame-based and frameless systems ("skin-to-skin" and "OR entry to exit").

resultsThe procedure proves to be safe. The entire procedure from fluoroscope positioning to the transfer to the planning station took 5-6 min with an image acquisition time of 24 s. In 5 of 6 cases, the fused imaging was able to reproduce the vascular anatomy accurately and in good quality. Both time end-points were significantly shorter compared to frame-based interventions.

conclusionThe images could easily be transferred to the planning and navigation system and were successfully merged with the MRI data set. The procedure can be completely integrated into the surgical workflow. Preoperative CT imaging or transport under anaesthesia may even be replaced by this technique in the future. Furthermore, hemorrhages can be successfully visualized intraoperatively and might prevent time delays in emergencies.

Indexed as

AgedAged, 80 and overBrain NeoplasmsCentral Nervous System Fungal InfectionsCerebral AngiographyCerebral HemorrhageContrast MediaFeasibility StudiesFluoroscopyHistoplasmosisHumansImage-Guided BiopsyImaging, Three-DimensionalInjections, IntravenousIntraoperative CareIodineContrast MediaIodine3 D rotational fluoroscopyFrameless systemsIntraoperative imagingNeurosurgeryStereotaxy

Identifiers

PMID34082701
PMCPMC8173902
OpenAlexW3129212914

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.