ArticleComputer methods and programs in biomedicine2021
The establishment of a 3D anatomical coordinate system for defining vaginal axis and spatial position.
Article in Computer methods and programs in biomedicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 8 citations in OpenAlex.
- Post-Hysterectomy Vaginal Vault Prolapse: Current Perspectives and Decision-Making Considerations for Surgical Treatment.Medicina (Kaunas, Lithuania) · 2026Review
- Urethral Morphology and Support Associated with Urinary Symptoms after Vaginal Surgery with and without Midurethral Sling.medRxiv : the preprint server for health sciences · 2026Article
- Sexual Function and Clitoral Anatomy after Vaginal Surgery with and without Midurethral Sling.medRxiv : the preprint server for health sciences · 2026Article
- Impact of rectal gas evacuation on dosimetry and applicator displacement in cervical cancer brachytherapy.Journal of applied clinical medical physics · 2026Article
- Racial differences in the levator ani muscle and levator hiatus in individuals of reproductive age.American journal of obstetrics and gynecology · 2025Article
- Vaginal morphology and position associated with prolapse recurrence after vaginal surgery: A secondary analysis of the DEMAND study.BJOG : an international journal of obstetrics and gynaecology · 2024Article
- The feasibility of uterine-vaginal axis MRI-based as evaluation of surgical efficacy in women with pelvic organ prolapse.Annals of translational medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
Abstract
BACKGROUND AND
objectivePelvic organ prolapse (POP), the herniation of the pelvic organs toward the vaginal opening, is a common pelvic floor disorder (PFD) whose etiology is poorly understood. Traditional methods for evaluating POP are often constrained to external vaginal examination, limited to 2D, or have poor reproducibility. We propose a reliable 3D anatomic coordinate system for standardized 3D assessment of pelvic anatomy using magnetic resonance imaging (MRI).
methodsThe novel 3D anatomic reference system is based on six bony landmarks of the pelvis manually identified in MRI: the ischial spines and the superior and inferior pubic points of the left and right pubic symphysis. The origin of this system is defined as the midpoint of the ischial spines. The reproducibility and applicability of the pelvic coordinate system were evaluated by (1) implementing it in a new method to quantify vaginal position and axis (angulation) in 3D space from MRI segmentations of the vagina and (2) computing the intraclass correlation (ICC) on coordinate system and vaginal measures. The MRI analysis was performed by four non-medically trained observers on five pelvic MRI datasets on approximately five separate occasions.
resultsOverall, all bony landmarks had excellent intra-observer reliability and inter-observer reliability (ICC>0.90); intra-observer reliability was moderate-to-good among the vaginal position parameters (0.5<ICC≤0.90) and moderate for the vaginal axis angles (0.50<ICC≤0.75); inter-observer reliability was moderate in the vaginal position coordinates and vaginal axis measures. On average, within-observer differences in the vaginal position and angle measures relative to the overall mean were <1 mm and <1°, respectively.
conclusionsThe proposed anatomic coordinate system and vaginal analysis approach allow quantitative assessment of pelvic anatomy that is robust to the experience level of the observer. The application of these methods in radiographic studies will give new insight into the underlying anatomic changes involved in the pathogenesis of POP and other PFDs and help better understand their etiology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.