Evidence map›Paper›PMID 34078363›Full record

ArticleBMC medical informatics and decision making2021

Development and implementation of an LIS-based validation system for autoverification toward zero defects in the automated reporting of laboratory test results.

Di Jin, Qing Wang, Dezhi Peng, Jiajia Wang, Bijuan Li, Yating Cheng, Nanxun Mo, Xiaoyan Deng, Ran Tao

Abstract read
In one paragraph

Article in BMC medical informatics and decision making, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Key Recommendations for Antimicrobial Resistance Surveillance: Takeaways From the CAPTURA Project.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2023
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Di JinLaboratory Diagnosis Department, Jinan Kingmed Center for Clinical Laboratory, Jinan, 250100, China.
Qing WangLaboratory Diagnosis Department, Jinan Kingmed Center for Clinical Laboratory, Jinan, 250100, China.
Dezhi PengLaboratory Diagnosis Department, Jinan Kingmed Center for Clinical Laboratory, Jinan, 250100, China.
Jiajia WangLaboratory Diagnosis Department, Jinan Kingmed Center for Clinical Laboratory, Jinan, 250100, China.
Bijuan LiClinical Laboratory Medicine, Guangzhou Medical University, Guangzhou, 510006, China.
Yating ChengClinical Laboratory Medicine, Guangzhou Medical University, Guangzhou, 510006, China.
Nanxun MoClinical Laboratory Medicine, Guangzhou Medical University, Guangzhou, 510006, China.
Xiaoyan DengClinical Laboratory Medicine, Guangzhou Medical University, Guangzhou, 510006, China.
Ran TaoClinical Laboratory Medicine, Guangzhou Medical University, Guangzhou, 510006, China. labtr@kingmed.com.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundValidation of the autoverification function is one of the critical steps to confirm its effectiveness before use. It is crucial to verify whether the programmed algorithm follows the expected logic and produces the expected results. This process has always relied on the assessment of human-machine consistency and is mostly a manually recorded and time-consuming activity with inherent subjectivity and arbitrariness that cannot guarantee a comprehensive, timely and continuous effectiveness evaluation of the autoverification function. To overcome these inherent limitations, we independently developed and implemented a laboratory information system (LIS)-based validation system for autoverification.

methodsWe developed a correctness verification and integrity validation method (hereinafter referred to as the "new method") in the form of a human-machine dialog. The system records personnel review steps and determines whether the human-machine review results are consistent. Laboratory personnel then analyze the reasons for any inconsistency according to system prompts, add to or modify rules, reverify, and finally improve the accuracy of autoverification.

resultsThe validation system was successfully established and implemented. For a dataset consisting of 833 rules for 30 assays, 782 rules (93.87%) were successfully verified in the correctness verification phase, and 51 rules were deleted due to execution errors. In the integrity validation phase, 24 projects were easily verified, while the other 6 projects still required the additional rules or changes to the rule settings. Taking the Hepatitis B virus test as an example, from the setting of 65 rules to the automated releasing of 3000 reports, the validation time was reduced from 452 (manual verification) to 275 h (new method), a reduction in validation time of 177 h. Furthermore, 94.6% (168/182) of laboratory users believed the new method greatly reduced the workload, effectively controlled the report risk and felt satisfied. Since 2019, over 3.5 million reports have been automatically reviewed and issued without a single clinical complaint.

conclusionTo the best of our knowledge, this is the first report to realize autoverification validation as a human-machine interaction. The new method effectively controls the risks of autoverification, shortens time consumption, and improves the efficiency of laboratory verification.

Indexed as

Clinical Laboratory Information SystemsAlgorithmsHumansAutoverificationCorrectness verificationHuman–computer interactionIntegrity validationLaboratory information systemRisk control

Identifiers

PMID34078363
PMCPMC8170738

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.