ArticleOrthopaedic surgery2021
Titanium Alloy Gamma Nail versus Biodegradable Magnesium Alloy Bionic Gamma Nail for Treating Intertrochanteric Fractures: A Finite Element Analysis.
Article in Orthopaedic surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 22 citations in OpenAlex.
- Machine learning prediction of post-traumatic osteoarthritis based on three-dimensional printing-derived joint congruence biomechanics in ankle fractures.Frontiers in medicine · 2026Article
- Magnesium-containing implants enhance bone healing: A mechanobiological perspective.Mechanobiology in medicine · 2025Review
- Finite element analysis of different cephalomedullary nail treatments for basicervical femoral neck fracture.Scientific reports · 2025Article
- Global trends in proximal femoral trabecular research: A bibliometric and visualized analysis.Journal of orthopaedics · 2025Article
- Biomechanical and clinically controlled study of different fenestration positions in vascularized iliac bone flaps for treating femoral head necrosis.Journal of orthopaedic surgery and research · 2025Article
- Effects of different reduction patterns on stress distribution in patients with intertrochanteric fractures with intramedullary nail fixation: a finite element analysis.Frontiers in bioengineering and biotechnology · 2025Article
- SrHPOMaterials today. Bio · 2024Article
- A Controlled Variable Study of the Biomechanical Properties of the Proximal Femur before and after Cancellous Bone Removal.Orthopaedic surgery · 2024Article
- Biomechanical optimization of the magnesium alloy bionic cannulated screw for stabilizing femoral neck fractures: a finite element analysis.Frontiers in bioengineering and biotechnology · 2024Article
- Biomechanical evaluation of ortho-bridge system and proximal femoral nail antirotation in intertrochanteric fractures with lateral wall fracture based on finite element analysis.Frontiers in bioengineering and biotechnology · 2024Article
- Mechanical Gains Associated With Virtual Prophylactic Intramedullary Nail Fixation in Femurs With Metastatic Disease.The Iowa orthopaedic journal · 2023Article
- Proximal femoral bionic nail-a novel internal fixation system for the treatment of femoral neck fractures: a finite element analysis.Frontiers in bioengineering and biotechnology · 2023Article
- Biomechanical study on the stability and strain conduction of intertrochanteric fracture fixed with proximal femoral nail antirotation versus triangular supporting intramedullary nail.International orthopaedics · 2022Article
- Feasibility analysis of an ultrasound on line diagnostic approach for oral and bone surgery.Scientific reports · 2022Article
- A comparative Study of Novel Extramedullary Fixation and Dynamic Hip Screw in the Fixation of Intertrochanteric Fracture: A Finite-Element Analysis.Frontiers in surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 1 country.
Funding
Abstract
objectiveTo using finite element analysis to investigate the effects of the traditional titanium alloy Gamma nail and a biodegradable magnesium alloy bionic Gamma nail for treating intertrochanteric fractures.
methodsComputed tomography images of an adult male volunteer of appropriate age and in good physical condition were used to establish a three-dimensional model of the proximal femur. Then, a model of a type 31A1 intertrochanteric fracture of the proximal femur was established, and the traditional titanium alloy Gamma nails and biodegradable magnesium alloy bionic Gamma nails were used for fixation, respectively. The von Mises stress, the maximum principal stress, and the minimum principal stress were calculated to evaluate the effect of bone ingrowth on stress distribution of the proximal femur after fixation.
resultsIn the intact model, the maximum stress was 5.8 MPa, the minimum stress was -11.7 MPa, and the von Mises stress was 11.4 MPa. The maximum principal stress distribution of the cancellous bone in the intact model appears in a position consistent with the growth direction of the principal and secondary tensile zones. After traditional Gamma nail healing, the maximum stress was 32 MPa, the minimum stress was -23.5 MPa, and the von Mises stress was 31.3 MPa. The stress concentration was quite obvious compared with the intact model. It was assumed that the nail would biodegrade completely within 12 months postoperatively. The maximum stress was 18.7 MPa, the minimum stress was -12.6 MPa, and the von Mises stress was 14.0 MPa. For the minimum principal stress, the region of minimum stress value less than -10 MPa was significantly improved compared with the traditional titanium alloy Gamma nail models. Meanwhile, the stress distribution of the bionic Gamma nail model in the proximal femur was closer to that of the intact bone, which significantly reduced the stress concentration of the implant.
conclusionThe biodegradable magnesium alloy bionic Gamma nail implant can improve the stress distribution of fractured bone close to that of intact bone while reducing the risk of postoperative complications associated with traditional internal fixation techniques, and it has promising clinical value in the future.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.