Evidence map›Paper›PMID 34073324›Full record

ArticleBioengineering (Basel, Switzerland)2021

In-House, Fast FDM Prototyping of a Custom Cutting Guide for a Lower-Risk Pediatric Femoral Osteotomy.

Leonardo Frizziero, Gian Maria Santi, Christian Leon-Cardenas, Giampiero Donnici, Alfredo Liverani, Paola Papaleo, Francesca Napolitano, Curzio Pagliari, Giovanni Luigi Di Gennaro, Stefano Stallone and 3 more

2 registry-linked trialsAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05700526 naenrolling by invitationnot on this mapstarted 2022, after this paper: background citation

Customized Bone Allografts by Virtual Surgical Planning and 3D-printing for Correcting Musculoskeletal Deformities in Children

TypeinterventionalSponsorIstituto Ortopedico RizzoliRan2022 to 2027Enrolled42ConditionsMusculoskeletal Deformity, Musculoskeletal Diseases, Musculoskeletal DisorderArmsPlanning of multiplanar and/or multifocal osteotomies in children by using VSP, PSIs and customized structural bone allograft, Routine preparation of bone graft according to standard protocols, Preparation of bone graft with virtual bone-matching and GSIs, Corrective osteotomy
NCT06380530 narecruitingnot on this mapstarted 2024, after this paper: background citation

Advanced Surgical Simulation Processes in the Correction of Skeletal Defects and Deformities

TypeinterventionalSponsorIstituto Ortopedico RizzoliRan2024 to 2029Enrolled100ConditionsMusculoskeletal Deformity, Musculoskeletal Abnormalities, Musculoskeletal DisorderArmsDeformity correction
3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Leonardo FrizzieroDepartment of Industrial Engineering, Alma Mater Studiorum University of Bologna, 40136 Bologna, Italy.ORCID 0000-0003-4809-3536
Gian Maria SantiDepartment of Industrial Engineering, Alma Mater Studiorum University of Bologna, 40136 Bologna, Italy.ORCID 0000-0002-7966-6002
Christian Leon-CardenasDepartment of Industrial Engineering, Alma Mater Studiorum University of Bologna, 40136 Bologna, Italy.ORCID 0000-0002-6430-4615
Giampiero DonniciDepartment of Industrial Engineering, Alma Mater Studiorum University of Bologna, 40136 Bologna, Italy.ORCID 0000-0002-6666-1309
Alfredo LiveraniDepartment of Industrial Engineering, Alma Mater Studiorum University of Bologna, 40136 Bologna, Italy.ORCID 0000-0002-3255-9381
Paola PapaleoDepartment of Industrial Engineering, Alma Mater Studiorum University of Bologna, 40136 Bologna, Italy.
Francesca NapolitanoDepartment of Industrial Engineering, Alma Mater Studiorum University of Bologna, 40136 Bologna, Italy.
Curzio PagliariDepartment of Industrial Engineering, Alma Mater Studiorum University of Bologna, 40136 Bologna, Italy.
Giovanni Luigi Di GennaroIRCCS-Istituto Ortopedico Rizzoli (Rizzoli Orthopaedic Institute), Paediatric Orthopaedics and Traumatology, 40136 Bologna, Italy.
Stefano StalloneIRCCS-Istituto Ortopedico Rizzoli (Rizzoli Orthopaedic Institute), Paediatric Orthopaedics and Traumatology, 40136 Bologna, Italy.
Stefano StilliIRCCS-Istituto Ortopedico Rizzoli (Rizzoli Orthopaedic Institute), Paediatric Orthopaedics and Traumatology, 40136 Bologna, Italy.
Giovanni TrisolinoIRCCS-Istituto Ortopedico Rizzoli (Rizzoli Orthopaedic Institute), Paediatric Orthopaedics and Traumatology, 40136 Bologna, Italy.ORCID 0000-0002-0361-9920
Paola ZarantonelloIRCCS-Istituto Ortopedico Rizzoli (Rizzoli Orthopaedic Institute), Paediatric Orthopaedics and Traumatology, 40136 Bologna, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Three-dimensional printed custom cutting guides (CCGs) are becoming more and more investigated in medical literature, as a patient-specific approach is often desired and very much needed in today's surgical practice. Three-dimensional printing applications and computer-aided surgical simulations (CASS) allow for meticulous preoperatory planning and substantial reductions of operating time and risk of human error. However, several limitations seem to slow the large-scale adoption of 3D printed CCGs. CAD designing and 3D printing skills are inevitably needed to develop workflow and address the study; therefore, hospitals are pushed to include third-party collaboration, from highly specialized medical centers to industrial engineering companies, thus increasing the time and cost of labor. The aim of this study was to move towards the feasibility of an in-house, low-cost CCG 3D printing methodology for pediatric orthopedic (PO) surgery. The prototype of a femoral cutting guide was developed for its application at the IOR-Rizzoli Orthopedic Institute of Bologna. The element was printed with an entry-level 3D printer with a high-temperature PLA fiber, whose thermomechanical properties can withstand common steam heat sterilization without bending or losing the original geometry. This methodology allowed for extensive preoperatory planning that would likewise reduce the overall surgery time, whilst reducing the risks related to the intervention.

Indexed as

3D printingCAD surgery simulationCASSCT scancutting guideorthopedic reproduction model

Identifiers

PMID34073324
PMCPMC8230284

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.