Evidence map›Paper›PMID 34072661›Full record

ArticleBiosensors2021

Plastic Antibody of Polypyrrole/Multiwall Carbon Nanotubes on Screen-Printed Electrodes for Cystatin C Detection.

Rui S Gomes, Blanca Azucena Gomez-Rodríguez, Ruben Fernandes, M Goreti F Sales, Felismina T C Moreira, Rosa F Dutra

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 33 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Rui S GomesBioMark@ISEP, School of Engineering, Polytechnic Institute of Porto, 4249-015 Porto, Portugal.
Blanca Azucena Gomez-RodríguezBiomedical Engineering Laboratory, Federal University of Pernambuco, Recife-PE 50670-901, Brazil.
Ruben FernandesLaBMI-PORTIC, Laboratory of Medical and Industrial Biotechnology-Porto Research, Technology & Innovation Centre, Polytechnic Institute of Porto, 4200-472 Porto, Portugal.ORCID 0000-0001-8933-3984
M Goreti F SalesBioMark@ISEP, School of Engineering, Polytechnic Institute of Porto, 4249-015 Porto, Portugal.ORCID 0000-0001-9936-7336
Felismina T C MoreiraBioMark@ISEP, School of Engineering, Polytechnic Institute of Porto, 4249-015 Porto, Portugal.ORCID 0000-0003-4237-8952
Rosa F DutraBiomedical Engineering Laboratory, Federal University of Pernambuco, Recife-PE 50670-901, Brazil.ORCID 0000-0001-8314-4218
Universidade Federal de Pernambuco · BRUniversity of Coimbra · PTi3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto · PTPolytechnic Institute of Porto · PT

Funding

CAPES 440605/2016-4Interreg 0624_2IQBIONEURO_6_E
6 · The paper itself

Abstract

This work reports the design of a novel plastic antibody for cystatin C (Cys-C), an acute kidney injury biomarker, and its application in point-of-care (PoC) testing. The synthetic antibody was obtained by tailoring a molecularly imprinted polymer (MIP) on a carbon screen-printed electrode (SPE). The MIP was obtained by electropolymerizing pyrrole (Py) with carboxylated Py (Py-COOH) in the presence of Cys-C and multiwall carbon nanotubes (MWCNTs). Cys-C was removed from the molecularly imprinted poly(Py) matrix (MPPy) by urea treatment. As a control, a non-imprinted poly(Py) matrix (NPPy) was obtained by the same procedure, but without Cys-C. The assembly of the MIP material was evaluated in situ by Raman spectroscopy and the binding ability of Cys-C was evaluated by the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) electrochemical techniques. The MIP sensor responses were measured by the DPV anodic peaks obtained in the presence of ferro/ferricyanide. The peak currents decreased linearly from 0.5 to 20.0 ng/mL of Cys-C at each 20 min successive incubation and a limit of detection below 0.5 ng/mL was obtained at pH 6.0. The MPPy/SPE was used to analyze Cys-C in spiked serum samples, showing recoveries <3%. This device showed promising features in terms of simplicity, cost and sensitivity for acute kidney injury diagnosis at the point of care.

Indexed as

Biosensing TechniquesCystatin CDielectric SpectroscopyElectrochemical TechniquesElectrodesHumansLimit of DetectionMolecular ImprintingNanotubes, CarbonPlasticsPolymersPyrrolesCST3 protein, humanCystatin CNanotubes, CarbonPlasticsPolymerspolypyrrolePyrrolesacute kidney injurycystatin Celectrochemical biosensormolecularly imprinted polymermultiwall carbon nanotubespolypyrene

Identifiers

PMID34072661
PMCPMC8228410
OpenAlexW3165101519

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.