Evidence map›Paper›PMID 34070412›Full record

ArticleSensors (Basel, Switzerland)2021

Novel Stable Capacitive Electrocardiogram Measurement System.

Chi-Chun Chen, Shu-Yu Lin, Wen-Ying Chang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Chi-Chun ChenDepartment of Electronic Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan.ORCID 0000-0002-8353-5603
Shu-Yu LinDepartment of Electronic Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan.
Wen-Ying ChangDepartment of Electronic Engineering, 3R Life Sciences Taiwan LTD, Kaohsiung 821, Taiwan.

Funding

Ministry of Science and Technology MOST 109-2221-E-167-002-MY3
6 · The paper itself

Abstract

This study presents a noncontact electrocardiogram (ECG) measurement system to replace conventional ECG electrode pads during ECG measurement. The proposed noncontact electrode design comprises a surface guard ring, the optimal input resistance, a ground guard ring, and an optimal voltage divider feedback. The surface and ground guard rings are used to reduce environmental noise. The optimal input resistor mitigates distortion caused by the input bias current, and the optimal voltage divider feedback increases the gain. Simulated gain analysis was subsequently performed to determine the most suitable parameters for the design, and the system was combined with a capacitive driven right leg circuit to reduce common-mode interference. The present study simulated actual environments in which interference is present in capacitive ECG signal measurement. Both in the case of environmental interference and motion artifact interference, relative to capacitive ECG electrodes, the proposed electrodes measured ECG signals with greater stability. In terms of R-R intervals, the measured ECG signals exhibited a 98.6% similarity to ECGs measured using contact ECG systems. The proposed noncontact ECG measurement system based on capacitive sensing is applicable for use in everyday life.

Indexed as

ArtifactsElectrocardiographyElectrodesMotionNoisenoncontact electrocardiogramoptimal input resistanceoptimal voltage divider feedbacksurface guard ring

Identifiers

PMID34070412
PMCPMC8197543