Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems.

Karl Martin Lehmann, Michael Weyhrauch, Monika Bjelopavlovic, Herbert Scheller, Henning Staedt, Peter Ottl, Peer W Kaemmerer, Stefan Wentaschek

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Karl Martin LehmannDepartment of Prosthodontics and Materials Science, University Medical Center of University of Mainz, Augustusplatz 2, 55131 Mainz, Germany.
Michael WeyhrauchDepartment of Prosthodontics and Materials Science, University Medical Center of University of Mainz, Augustusplatz 2, 55131 Mainz, Germany.
Monika BjelopavlovicDepartment of Prosthodontics and Materials Science, University Medical Center of University of Mainz, Augustusplatz 2, 55131 Mainz, Germany.
Herbert SchellerDepartment of Prosthodontics and Materials Science, University Medical Center of University of Mainz, Augustusplatz 2, 55131 Mainz, Germany.
Henning StaedtDepartment of Prosthodontics and Materials Science, University of Rostock, Strempelstr. 13, 18057 Rostock, Germany.
Peter OttlDepartment of Prosthodontics and Materials Science, University of Rostock, Strempelstr. 13, 18057 Rostock, Germany.
Peer W KaemmererDepartment of Oral- and Maxillofacial Surgery, University Medical Center of University of Mainz, Augustusplatz 2, 55131 Mainz, Germany.ORCID 0000-0002-1671-3764
Stefan WentaschekDepartment of Prosthodontics and Materials Science, University Medical Center of University of Mainz, Augustusplatz 2, 55131 Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. PURPOSE: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems. MATERIALS AND

methodsPrepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A-D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferroni adjustment was performed. The global level of significance was set at 5%.

resultsThe mean gap size ranged from 84 to 132 µm (SD 43-71 µm). The CAD/CAM systems showed significant variance (

conclusionsThe CAD/CAM systems showed significantly different gap sizes, particularly between premolars and molars and among the marginal, axial and occlusal regions. All of the systems are suitable for clinical application.

Indexed as

CAD/CAMFPDinternal fitmarginal fitzirconia

Identifiers

PMID34069551
PMCPMC8161266

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.