Evidence map›Paper›PMID 34069085›Full record

ArticleSensors (Basel, Switzerland)2021

Automated Quality Assessment of Interferometric Ring Laser Data.

Andreas Brotzer, Felix Bernauer, Karl Ulrich Schreiber, Joachim Wassermann, Heiner Igel

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Rotation Rate Sensors and Their Applications.Sensors (Basel, Switzerland) · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Andreas BrotzerDepartment of Earth and Environmental Sciences, Ludwig Maximilian University Munich, Theresienstr. 41, D-80333 Munich, Germany.ORCID 0000-0003-2422-7907
Felix BernauerDepartment of Earth and Environmental Sciences, Ludwig Maximilian University Munich, Theresienstr. 41, D-80333 Munich, Germany.ORCID 0000-0002-9509-4905
Karl Ulrich SchreiberGeodetic Observatory Wettzell, Research Unit Satellite Geodesy, Technical University of Munich, 93444 Bad Koetzting, Germany.ORCID 0000-0002-3775-5058
Joachim WassermannDepartment of Earth and Environmental Sciences, Ludwig Maximilian University Munich, Theresienstr. 41, D-80333 Munich, Germany.ORCID 0000-0002-4088-1792
Heiner IgelDepartment of Earth and Environmental Sciences, Ludwig Maximilian University Munich, Theresienstr. 41, D-80333 Munich, Germany.ORCID 0000-0002-7242-6399

Funding

European Research Council 339991Ludwig-Maximilians-Universität München No specific Number
6 · The paper itself

Abstract

In seismology, an increased effort to observe all 12 degrees of freedom of seismic ground motion by complementing translational ground motion observations with measurements of strain and rotational motions could be witnessed in recent decades, aiming at an enhanced probing and understanding of Earth and other planetary bodies. The evolution of optical instrumentation, in particular large-scale ring laser installations, such as G-ring and ROMY (ROtational Motion in seismologY), and their geoscientific application have contributed significantly to the emergence of this scientific field. The currently most advanced, large-scale ring laser array is ROMY, which is unprecedented in scale and design. As a heterolithic structure, ROMY's ring laser components are subject to optical frequency drifts. Such Sagnac interferometers require new considerations and approaches concerning data acquisition, processing and quality assessment, compared to conventional, mechanical instrumentation. We present an automated approach to assess the data quality and the performance of a ring laser, based on characteristics of the interferometric Sagnac signal. The developed scheme is applied to ROMY data to detect compromised operation states and assign quality flags. When ROMY's database becomes publicly accessible, this assessment will be employed to provide a quality control feature for data requests.

Indexed as

data quality controlring laser data processingROMYrotational seismologyrotation rate sensorsSagnac effect

Identifiers

PMID34069085
PMCPMC8156557

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.