Evidence map›Paper›PMID 34068978›Full record

ArticlePharmaceutics2021

Detection of Breathing Movements of Preterm Neonates by Recording Their Abdominal Movements with a Time-of-Flight Camera.

Felix C Wiegandt, David Biegger, Jacob F Fast, Grzegorz Matusiak, Jan Mazela, Tobias Ortmaier, Theodor Doll, Andreas Dietzel, Bettina Bohnhorst, Gerhard Pohlmann

Abstract read
In one paragraph

Article in Pharmaceutics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Felix C WiegandtDivision of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany.ORCID 0000-0003-0753-4497
David BieggerDivision of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany.
Jacob F FastInstitute of Mechatronic Systems, Leibniz Universität Hannover, 30823 Garbsen, Germany.ORCID 0000-0002-0651-8279
Grzegorz MatusiakDivision of Infectious Diseases, Department of Neonatology, Poznan University of Medical Sciences, 61-701 Poznan, Poland.
Jan MazelaDivision of Infectious Diseases, Department of Neonatology, Poznan University of Medical Sciences, 61-701 Poznan, Poland.
Tobias OrtmaierInstitute of Mechatronic Systems, Leibniz Universität Hannover, 30823 Garbsen, Germany.
Theodor DollDivision of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany.
Andreas DietzelInstitute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany.ORCID 0000-0003-2090-6259
Bettina BohnhorstDepartment of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, 30625 Hannover, Germany.
Gerhard PohlmannDivision of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany.

Funding

German Federal Ministry of Education and Research GS2SH016Horizon 2020 Framework Programme 814654
6 · The paper itself

Abstract

In order to deliver an aerosolized drug in a breath-triggered manner, the initiation of the patient's inspiration needs to be detected. The best-known systems monitoring breathing patterns are based on flow sensors. However, due to their large dead space volume, flow sensors are not advisable for monitoring the breathing of (preterm) neonates. Newly-developed respiratory sensors, especially when contact-based (invasive), can be tested on (preterm) neonates only with great effort due to clinical and ethical hurdles. Therefore, a physiological model is highly desirable to validate these sensors. For developing such a system, abdominal movement data of (preterm) neonates are required. We recorded time sequences of five preterm neonates' abdominal movements with a time-of-flight camera and successfully extracted various breathing patterns and respiratory parameters. Several characteristic breathing patterns, such as forced breathing, sighing, apnea and crying, were identified from the movement data. Respiratory parameters, such as duration of inspiration and expiration, as well as respiratory rate and breathing movement over time, were also extracted. This work demonstrated that respiratory parameters of preterm neonates can be determined without contact. Therefore, such a system can be used for breathing detection to provide a trigger signal for breath-triggered drug release systems. Furthermore, based on the recorded data, a physiological abdominal movement model of preterm neonates can now be developed.

Indexed as

abdominal movementoptical detection of breathing movementspreterm neonatetime-of-flight camera

Identifiers

PMID34068978
PMCPMC8156597

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.