ReviewInternational journal of molecular sciences2021
Molecular Imprinting Technology for Determination of Uric Acid.
Review in International journal of molecular sciences, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 59 citations in OpenAlex.
- [Research progress in the application of molecular imprinting technology in catalysis].Se pu = Chinese journal of chromatography · 2026Article
- Electrochemical Detection of Levofloxacin Using a Polydopamine-Based Molecular Imprinting Polymer.Molecules (Basel, Switzerland) · 2025Article
- Association between the serum uric acid-to-high-density lipoprotein cholesterol ratio and microalbuminuria in individuals with type 2 diabetes mellitus.European journal of medical research · 2025Article
- Overcoming Template Surface Blocking: Geraniol Adsorption Studies Guiding MIP-Based Sensor Design.International journal of molecular sciences · 2025Article
- Platelet-Rich Plasma and Electrochemical Biosensors: A Novel Approach to Ovarian Function Evaluation and Diagnostics.International journal of molecular sciences · 2025Review
- Toward the development of a specific non-enzymatic amperometric sensor for determining uric acid in fermentation samples.Mikrochimica acta · 2025Article
- Emerging trends in functional molecularly imprinted polymers for electrochemical detection of biomarkers.Biomicrofluidics · 2024Review
- 4,5-Diamino-2-Thiouracil-Powered Dual-Mode Biosensor for Sensitive, Nonenzymatic Determination of Saliva Uric Acid Levels.International journal of analytical chemistry · 2024Article
- Molecularly Imprinted Polymer-Based Electrochemical Sensors for the Diagnosis of Infectious Diseases.Biosensors · 2023Review
- Molecularly Imprinted Polymers for the Determination of Cancer Biomarkers.International journal of molecular sciences · 2023Review
- Review
- An Efficient Enzyme-Less Uric Acid Sensor Development Based on PbO-Doped NiO Nanocomposites.Biosensors · 2022Article
- Selectivity Enhancement for Uric Acid Detection viaACS omega · 2022Article
- A facile electrochemical sensor based on a composite of electrochemically reduced graphene oxide and a PEDOT:PSS modified glassy carbon electrode for uric acid detection.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2022Article
- Thermal Detection of Glucose in Urine Using a Molecularly Imprinted Polymer as a Recognition Element.ACS sensors · 2021Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
Abstract
The review focuses on the overview of electrochemical sensors based on molecularly imprinted polymers (MIPs) for the determination of uric acid. The importance of robust and precise determination of uric acid is highlighted, a short description of the principles of molecular imprinting technology is presented, and advantages over the others affinity-based analytical methods are discussed. The review is mainly concerned with the electro-analytical methods like cyclic voltammetry, electrochemical impedance spectroscopy, amperometry, etc. Moreover, there are some scattered notes to the other electrochemistry-related analytical methods, which are capable of providing additional information and to solve some challenges that are not achievable using standard electrochemical methods. The significance of these overviewed methods is highlighted. The overview of the research that is employing MIPs imprinted with uric acid is mainly targeted to address these topics: (i) type of polymers, which are used to design uric acid imprint structures; (ii) types of working electrodes and/or other parts of signal transducing systems applied for the registration of analytical signal; (iii) the description of the uric acid extraction procedures applied for the design of final MIP-structure; (iv) advantages and disadvantages of electrochemical methods and other signal transducing methods used for the registration of the analytical signal; (vi) overview of types of interfering molecules, which were analyzed to evaluate the selectivity; (vi) comparison of analytical characteristics such as linear range, limits of detection and quantification, reusability, reproducibility, repeatability, and stability. Some insights in future development of uric acid sensors are discussed in this review.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.