ArticleMaterials (Basel, Switzerland)2021

A Comparison of Biomechanical Properties of Implant-Retained Overdenture Based on Precision Attachment Type.

Małgorzata Idzior-Haufa, Agnieszka A Pilarska, Wiesław Hędzelek, Piotr Boniecki, Krzysztof Pilarski, Barbara Dorocka-Bobkowska

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Małgorzata Idzior-HaufaDepartment of Gerodontology and Oral Pathology, Poznan University of Medical Sciences, Bukowska Street 70, 60-812 Poznan, Poland.
Agnieszka A PilarskaDepartment of Plant-Derived Food Technology, Poznań University of Life Sciences, ul. Wojska Polskiego 31, 60-624 Poznan, Poland.ORCID 0000-0001-6128-0315
Wiesław HędzelekDepartment of Prosthodontics, Poznan University of Medical Sciences, Bukowska Street 70, 60-812 Poznań, Poland.
Piotr BonieckiDepartment of Biosystems Engineering, Poznań University of Life Sciences, ul. Wojska Polskiego 50, 60-627 Poznan, Poland.
Krzysztof PilarskiDepartment of Biosystems Engineering, Poznań University of Life Sciences, ul. Wojska Polskiego 50, 60-627 Poznan, Poland.
Barbara Dorocka-BobkowskaDepartment of Gerodontology and Oral Pathology, Poznan University of Medical Sciences, Bukowska Street 70, 60-812 Poznan, Poland.ORCID 0000-0003-3659-7761
Poznan University of Medical Sciences · PLUniversity of Life Sciences in Poznań · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper aims to compare, in vitro, the biomechanical properties of an overdenture retained by two bar-retained implants and an overdenture retained by two bar-retained implants with ball attachments. An edentulous mandible model was prepared for the study based on the FRASACO mold with two implants. In the first system, the "rider" type (PRECI-HORIX, CEKA) retention structure and the complete mandibular denture with the matrix were made. In the second system, the "rider" type retention suprastructure was also used. In the distal part, (CEKA) clips were placed symmetrically, and a complete mandibular denture, together with the matrix on the bar, and the clip patrices were made. A numerical model was developed for each system where all elements were positioned and related to geometric relations, as in reality. The FEA analysis (finite element analysis) was carried out for seven types of loads: with vertical forces of 20, 50, and 100 N and oblique forces of 20 and 50 N acting on individual teeth of the denture, namely central incisor, canine, and first molar. Displacements, stresses, and deformations within the systems were investigated. Maximum denture displacement in the first system was 0.7 mm. Maximum bar stress amounted to 27.528 MPa, and implant stress to 23.16 MPa. Maximum denture displacement in the second system was 0.6 mm. Maximum bar stress amounted to 578.6 MPa, that of clips was 136.99 MPa, and that of implants was 51.418 MPa. Clips cause smaller displacement of the overdenture when it is loaded but generate higher stress within the precision elements and implants compared to a denture retained only by a bar. Regardless of the shape of the precision element, small deformations occur that mainly affect the mucosa and the matrix.

Indexed as

barfinite element analysisimplantmandibleoverdenture

Identifiers

PMID34067572
PMCPMC8155947
OpenAlexW3162380972

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked