Evidence map›Paper›PMID 34067495›Full record

ArticlePolymers2021

Sonication-Assisted Method for Decellularization of Human Umbilical Artery for Small-Caliber Vascular Tissue Engineering.

Chih-Hsun Lin, Kai Hsia, Chih-Kuan Su, Chien-Chin Chen, Chang-Ching Yeh, Hsu Ma, Jen-Her Lu

Abstract read
In one paragraph

Article in Polymers, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Tissue compliance characterization for human umbilical arteries after decellularization.Journal of the mechanical behavior of biomedical materials · 2026
    Article
  2. Review
  3. Review
  4. Review
  5. Review
  6. Review
  7. Review
  8. Review
  9. Review
  10. Review
  11. The journey of decellularized vessel: from laboratory to operating room.Frontiers in bioengineering and biotechnology · 2024
    Review
  12. Article
  13. Review
  14. Review
  15. Review
  16. Review
  17. Review
  18. Review
  19. Review
  20. Recent Advances in Liver Engineering With Decellularized Scaffold.Frontiers in bioengineering and biotechnology · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Chih-Hsun LinDivision of Plastic and Reconstructive Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei 11217, Taiwan.ORCID 0000-0002-9771-5816
Kai HsiaDivision of Plastic and Reconstructive Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei 11217, Taiwan.
Chih-Kuan SuDivision of Plastic and Reconstructive Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei 11217, Taiwan.
Chien-Chin ChenDepartment of Pathology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi 600, Taiwan.ORCID 0000-0001-9599-0884
Chang-Ching YehDepartment of Obstetrics and Gynecology, Taipei Veterans General Hospital, Taipei 11217, Taiwan.ORCID 0000-0003-0690-7503
Hsu MaDivision of Plastic and Reconstructive Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei 11217, Taiwan.
Jen-Her LuSection of Pediatric Cardiology, Department of Pediatrics, Taipei Medical University Hospital, Taipei 11031, Taiwan.ORCID 0000-0003-2056-3065

Funding

Ministry of Science and Technology, Taiwan MoST108-2314-B-075 -053, 108-2314-B-075 -045, and MOST 109-2314-B-075 -007
6 · The paper itself

Abstract

Decellularized vascular grafts are useful for the construction of biological small-diameter tissue-engineered vascular grafts (≤6 mm). Traditional chemical decellularization requires a long treatment time, which may damage the structure and alter the mechanical properties. Decellularization using sonication is expected to solve this problem. The aim of this study was to develop an effective decellularization method using ultrasound followed by washing. Different power values of sonication at 40 kHz were tested for 2, 4, and 8 h followed by a washing procedure. The efficacy of sonication of decellularized human umbilical artery (sDHUA) was evaluated via DNA content, histological staining, mechanical properties, and biocompatibility. The sDHUAs were further implanted into rats for up to 90 days and magnetic resonance angiography (MRA) was performed for the implanted grafts. The results demonstrated that treatment of human umbilical artery (HUA) by sonication at ultrasonic power of 204 W for 4 h followed by washing for 24 h in 2% SDS buffer could eliminate more than 90% of cells and retain similar mechanical properties of the HUA. Recellularization was assessed by scanning electron microscopy (SEM), which indicated that sDHUA provided niches for human umbilical vein endothelial cells (HUVECs) to reside, indicating in vitro cytocompatibility. Further implantation tests also indicated the fitness of the sonication-treated HUA as a scaffold for small-caliber tissue engineering vascular grafts.

Indexed as

biocompatibilityextracellular matrixrecellularizationsonication decellularized human umbilical arteryultrasonic decellularization

Identifiers

PMID34067495
PMCPMC8196986

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.