Evidence map›Paper›PMID 34067051›Full record

ArticleSensors (Basel, Switzerland)2021

Autoencoder-Based Extrasystole Detection and Modification of RRI Data for Precise Heart Rate Variability Analysis.

Koichi Fujiwara, Shota Miyatani, Asuka Goda, Miho Miyajima, Tetsuo Sasano, Manabu Kano

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Koichi FujiwaraDepartment of Material Process Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8601, Japan.ORCID 0000-0002-2929-0561
Shota MiyataniDepartment of Systems Science, Kyoto University, Kyoto 606-8501, Japan.
Asuka GodaDepartment of Systems Science, Kyoto University, Kyoto 606-8501, Japan.
Miho MiyajimaDepartment of Liaison Psychiatry and Palliative Medicine, Tokyo Medical and Dental University, Tokyo 113-8510, Japan.
Tetsuo SasanoDepartment of Liaison Psychiatry and Palliative Medicine, Tokyo Medical and Dental University, Tokyo 113-8510, Japan.
Manabu KanoDepartment of Systems Science, Kyoto University, Kyoto 606-8501, Japan.ORCID 0000-0002-2325-1043
Kyoto University · JPTokyo Medical and Dental University · JPNagoya University · JP

Funding

Japan Science and Technology Agency PRESTO JPMJPR1859Japan Society for the Promotion of Science KAKENHI #19H04501
6 · The paper itself

Abstract

Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified appropriately before HRV analysis. In this study, we consider two types of extrasystoles-premature ventricular contraction (PVC) and premature atrial contraction (PAC)-which are types of extrasystoles that occur every day, even in healthy persons who have no cardiovascular diseases. A unified framework for ectopic RRI detection and a modification algorithm that utilizes an autoencoder (AE) type of neural network is proposed. The proposed framework consists of extrasystole occurrence detection from the RRI data and modification, whose targets are PVC and PAC. The RRI data are monitored by means of the AE in real time in the detection phase, and a denoising autoencoder (DAE) modifies the ectopic RRI caused by the detected extrasystole. These are referred to as AE-based extrasystole detection (AED) and DAE-based extrasystole modification (DAEM), respectively. The proposed framework was applied to real RRI data with PVC and PAC. The result showed that AED achieved a sensitivity of 93% and a false positive rate of 0.08 times per hour. The root mean squared error of the modified RRI decreased to 31% in PVC and 73% in PAC from the original RRI data by DAEM. In addition, the proposed framework was validated through application to a clinical epileptic seizure problem, which showed that it correctly suppressed the false positives caused by PVC. Thus, the proposed framework can contribute to realizing accurate HRV-based health monitoring and medical sensing systems.

Indexed as

Cardiac Complexes, PrematureElectrocardiographyAlgorithmsHeart RateHumansNeural Networks, Computerautoencoderextrasystoleheart rate variability analysismachine learningRRI data

Identifiers

PMID34067051
PMCPMC8125061
OpenAlexW3159045994

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked