Evidence map›Paper›PMID 34065449›Full record

ArticleSensors (Basel, Switzerland)2021

A Capacitive 3-Axis MEMS Accelerometer for Medipost: A Portable System Dedicated to Monitoring Imbalance Disorders.

Michał Szermer, Piotr Zając, Piotr Amrozik, Cezary Maj, Mariusz Jankowski, Grzegorz Jabłoński, Rafał Kiełbik, Jacek Nazdrowicz, Małgorzata Napieralska, Bartosz Sakowicz

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Michał SzermerDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.ORCID 0000-0002-9294-701X
Piotr ZającDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.
Piotr AmrozikDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.
Cezary MajDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.
Mariusz JankowskiDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.
Grzegorz JabłońskiDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.ORCID 0000-0003-0376-3583
Rafał KiełbikDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.
Jacek NazdrowiczDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.
Małgorzata NapieralskaDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.
Bartosz SakowiczDepartment of Microelectronics and Computer Science, Lodz University of Technology, 93-005 Lodz, Poland.

Funding

Narodowe Centrum Badań i Rozwoju 2/266299/19NCBR/2016
6 · The paper itself

Abstract

The constant development and miniaturization of MEMS sensors invariably provides new possibilities for their use in health-related and medical applications. The application of MEMS devices in posturographic systems allows faster diagnosis and significantly facilitates the work of medical staff. MEMS accelerometers constitute a vital part of such systems, particularly those intended for monitoring patients with imbalance disorders. The correct design of such sensors is crucial for gathering data about patient movement and ensuring the good overall performance of the entire system. This paper presents the design and measurements of a three-axis accelerometer dedicated for use in a device which tracks patient movement. Its main focus is the characterization of the sensor, comparing different designs and evaluating the impact of the packaging and readout circuit integration on sensor operation. Extensive testing and measurements confirm that the designed accelerometer works correctly and allows identifying the best design in terms of sensitivity/stability. Moreover, the response of the proposed sensor as a function of the applied acceleration demonstrates very good linearity only if the readout circuit is integrated in the same package as the MEMS sensor.

Indexed as

Micro-Electrical-Mechanical SystemsAccelerationAccelerometryHumansMonitoring, PhysiologicMovementASIC readout circuitimbalance disordersMEMS accelerometerportable system

Identifiers

PMID34065449
PMCPMC8161350

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.