Evidence map›Paper›PMID 34064464›Full record

ArticleInternational journal of environmental research and public health2021

Evaluation of a Wearable Non-Invasive Thermometer for Monitoring Ear Canal Temperature during Physically Demanding (Outdoor) Work.

Charlotte Christina Roossien, Audy Paul Hodselmans, Ronald Heus, Michiel Felix Reneman, Gijsbertus Jacob Verkerke

Abstract read
In one paragraph

Article in International journal of environmental research and public health, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. External auditory exostosis among surfers: a comprehensive and systematic review.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024
    Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Charlotte Christina RoossienDepartment of Rehabilitation, University of Groningen, University Medical Center Groningen, Medicine, 9713 GZ Groningen, The Netherlands.ORCID 0000-0001-6489-6967
Audy Paul HodselmansCenter for Applied Research and Innovation in Health Care and in Nursing, Hanze University of Applied Sciences, 9747 AS Groningen, The Netherlands.
Ronald HeusInstitute for Safety (IFV), Knowledge Center Occupational Safety, 6816 RW Arnhem, The Netherlands.
Michiel Felix RenemanDepartment of Rehabilitation, University of Groningen, University Medical Center Groningen, Medicine, 9713 GZ Groningen, The Netherlands.
Gijsbertus Jacob VerkerkeDepartment of Rehabilitation, University of Groningen, University Medical Center Groningen, Medicine, 9713 GZ Groningen, The Netherlands.ORCID 0000-0003-3533-2446

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aimed at preventing heat strain, health problems, and absenteeism among workers with physically demanding occupations, a continuous, accurate, non-invasive measuring system may help such workers monitor their body (core) temperature. The aim of this study is to evaluate the accuracy and explore the usability of the wearable non-invasive Cosinuss° °Temp thermometer. Ear canal temperature was monitored in 49 workers in real-life working conditions. After individual correction, the results of the laboratory and field study revealed high correlations compared to ear canal infrared thermometry for hospital use. After performance of the real-life working tasks, this correlation was found to be moderate. It was also observed that the ambient environmental outdoor conditions and personal protective clothing influenced the accuracy and resulted in unrealistic ear canal temperature outliers. It was found that the Cosinuss° °Temp thermometer did not result in significant interference during work. Therefore, it was concluded that, without a correction factor, the Cosinuss° °Temp thermometer is inaccurate. Nevertheless, with a correction factor, the reliability of this wearable ear canal thermometer was confirmed at rest, but not in outdoor working conditions or while wearing a helmet or hearing protection equipment.

Indexed as

ThermometersWearable Electronic DevicesBody TemperatureEar CanalHumansReproducibility of ResultsTemperatureheat strainoverheatingthermal physiology

Identifiers

PMID34064464
PMCPMC8125248

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials