Evidence map›Paper›PMID 34064090›Full record

ArticleBiomedicines2021

Hemostatic and Tissue Regeneration Performance of Novel Electrospun Chitosan-Based Materials.

Volodymyr Deineka, Oksana Sulaieva, Mykola Pernakov, Viktoriia Korniienko, Yevheniia Husak, Anna Yanovska, Aziza Yusupova, Yuliia Tkachenko, Oksana Kalinkevich, Alena Zlatska and 1 more

Abstract read
In one paragraph

Article in Biomedicines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Volodymyr DeinekaMedical Institute, Sumy State University, 40007 Sumy, Ukraine.
Oksana SulaievaMedical Institute, Sumy State University, 40007 Sumy, Ukraine.
Mykola PernakovMedical Institute, Sumy State University, 40007 Sumy, Ukraine.ORCID 0000-0002-7048-7446
Viktoriia KorniienkoMedical Institute, Sumy State University, 40007 Sumy, Ukraine.
Yevheniia HusakMedical Institute, Sumy State University, 40007 Sumy, Ukraine.
Anna YanovskaMedical Institute, Sumy State University, 40007 Sumy, Ukraine.ORCID 0000-0001-8040-7457
Aziza YusupovaMedical Institute, Sumy State University, 40007 Sumy, Ukraine.
Yuliia TkachenkoMedical Institute, Sumy State University, 40007 Sumy, Ukraine.ORCID 0000-0002-0699-5585
Oksana KalinkevichInstitute of Applied Physics, 40000 Sumy, Ukraine.
Alena ZlatskaBiotechnology Laboratory Ilaya Regeneration, Medical Company Ilaya, 03115 Kyiv, Ukraine.
Maksym PogorielovMedical Institute, Sumy State University, 40007 Sumy, Ukraine.ORCID 0000-0001-9372-7791

Funding

H2020 Marie Skłodowska-Curie Actions 777926Ministry of Educatona and Science of Ukraine 0120U101972
6 · The paper itself

Abstract

The application of chitosan (Ch) as a promising biopolymer with hemostatic properties and high biocompatibility is limited due to its prolonged degradation time, which, in turn, slows the repair process. In the present research, we aimed to develop new technologies to reduce the biodegradation time of Ch-based materials for hemostatic application. This study was undertaken to assess the biocompatibility and hemostatic and tissue-regeneration performance of Ch-PEO-copolymer prepared by electrospinning technique. Chitosan electrospinning membranes (ChEsM) were made from Ch and polyethylene oxide (PEO) powders for rich high-porous material with sufficient hemostatic parameters. The structure, porosity, density, antibacterial properties, in vitro degradation and biocompatibility of ChEsM were evaluated and compared to the conventional Ch sponge (ChSp). In addition, the hemostatic and bioactive performance of both materials were examined in vivo, using the liver-bleeding model in rats. A penetrating punch biopsy of the left liver lobe was performed to simulate bleeding from a non-compressible irregular wound. Appropriately shaped ChSp or ChEsM were applied to tissue lesions. Electrospinning allows us to produce high-porous membranes with relevant ChSp degradation and swelling properties. Both materials demonstrated high biocompatibility and hemostatic effectiveness in vitro. However, the antibacterial properties of ChEsM were not as good when compared to the ChSp. In vivo studies confirmed superior ChEsM biocompatibility and sufficient hemostatic performance, with tight interplay with host cells and tissues. The in vivo model showed a higher biodegradation rate of ChEsM and advanced liver repair.

Indexed as

chitosanelectrospinninghemostasisregeneration

Identifiers

PMID34064090
PMCPMC8224387

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.