Evidence map›Paper›PMID 34063347›Full record

ArticleSensors (Basel, Switzerland)2021

A Surface Plasmon Resonance Plastic Optical Fiber Biosensor for the Detection of Pancreatic Amylase in Surgically-Placed Drain Effluent.

Laura Pasquardini, Nunzio Cennamo, Giuseppe Malleo, Lia Vanzetti, Luigi Zeni, Deborah Bonamini, Roberto Salvia, Claudio Bassi, Alessandra Maria Bossi

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.8field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Laura PasquardiniIndivenire srl, Via Alla Cascata 56/C, 38123 Trento, Italy.ORCID 0000-0001-9171-7856
Nunzio CennamoDepartment of Engineering, University of Campania "L. Vanvitelli", Via Roma 29, 81031 Aversa, Italy.ORCID 0000-0001-7769-0984
Giuseppe MalleoUnit of Pancreatic Surgery, University of Verona Hospital Trust, Department of Surgery, Dentistry, Gynecology and Pediatrics (DSCOMI), University of Verona, P. le Scuro 10, 37134 Verona, Italy.
Lia VanzettiFondazione Bruno Kessler-Sensors&Devices e Micro Nano Facility, Via Sommarive 18, 38123 Povo-Trento, Italy.
Luigi ZeniDepartment of Engineering, University of Campania "L. Vanvitelli", Via Roma 29, 81031 Aversa, Italy.
Deborah BonaminiUnit of Pancreatic Surgery, University of Verona Hospital Trust, Department of Surgery, Dentistry, Gynecology and Pediatrics (DSCOMI), University of Verona, P. le Scuro 10, 37134 Verona, Italy.
Roberto SalviaUnit of Pancreatic Surgery, University of Verona Hospital Trust, Department of Surgery, Dentistry, Gynecology and Pediatrics (DSCOMI), University of Verona, P. le Scuro 10, 37134 Verona, Italy.
Claudio BassiUnit of Pancreatic Surgery, University of Verona Hospital Trust, Department of Surgery, Dentistry, Gynecology and Pediatrics (DSCOMI), University of Verona, P. le Scuro 10, 37134 Verona, Italy.
Alessandra Maria BossiDepartment of Biotechnology, University of Verona, Strada Le Grazie 15, 37134 Verona, Italy.ORCID 0000-0002-2542-8412
University of Verona · ITUniversity of Campania "Luigi Vanvitelli" · ITFondazione Bruno Kessler · IT

Funding

Università degli Studi della Campania Luigi Vanvitelli VALERE
6 · The paper itself

Abstract

Postoperative pancreatic fistula (POPF), the major driver of morbidity and mortality following pancreatectomy, is caused by an abnormal communication between the pancreatic ductal epithelium and another epithelial surface containing pancreas-derived, enzyme-rich fluid. There is a strong correlation between the amylase content in surgically-placed drains early in the postoperative course and the development of POPF. A simple and cheap method to determine the amylase content from the drain effluent has been eagerly advocated. Here, we developed an amylase optical biosensor, based on a surface plasmon resonance (SPR) plastic optical fiber (POF), metallized with a 60 nm layer of gold and interrogated with white light. The sensor was made specific by coupling it with an anti-amylase antibody. Each surface derivatization step was optimized and studied by XPS, contact angle, and fluorescence. The POF-biosensor was tested for its response to amylase in diluted drain effluents. The volume of sample required was 50 µL and the measurement time was 8 min. The POF-biosensor showed selectivity for amylase, a calibration curve log-linear in the range of 0.8-25.8 U/L and a limit of detection (LOD) of ~0.5 U/L. In preliminary tests, the POF-biosensor allowed for the measurement of the amylase content of diluted surgically-placed drain effluents with an accuracy of >92% with respect to the gold standard. The POF-biosensor allows for reliable measurement and could be implemented to allow for a rapid bedside assessment of amylase value in drains following pancreatectomy.

Indexed as

Biosensing TechniquesSurface Plasmon ResonanceAmylasesDrainageHumansOptical FibersPancreasPancreatectomyPancreatic FistulaPlasticsAmylasesPlasticsamylaseantibodyoptical fiber sensorsplastic optical fiberspostoperative pancreatic fistulasurface plasmon resonance

Identifiers

PMID34063347
PMCPMC8156063
OpenAlexW3160057301

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked