Evidence map›Paper›PMID 34062903›Full record

ArticleMicromachines2021

Smart Fall Detection Framework Using Hybridized Video and Ultrasonic Sensors.

Feng-Shuo Hsu, Tang-Chen Chang, Zi-Jun Su, Shin-Jhe Huang, Chien-Chang Chen

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Feng-Shuo HsuDepartment of Psychiatry, Taichung Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taichung 42743, Taiwan.
Tang-Chen ChangBio-Microsystems Integration Laboratory, Department of Biomedical Sciences and Engineering, National Central University, Taoyuan City 32001, Taiwan.ORCID 0000-0002-9529-9070
Zi-Jun SuBio-Microsystems Integration Laboratory, Department of Biomedical Sciences and Engineering, National Central University, Taoyuan City 32001, Taiwan.
Shin-Jhe HuangBio-Microsystems Integration Laboratory, Department of Biomedical Sciences and Engineering, National Central University, Taoyuan City 32001, Taiwan.
Chien-Chang ChenBio-Microsystems Integration Laboratory, Department of Biomedical Sciences and Engineering, National Central University, Taoyuan City 32001, Taiwan.ORCID 0000-0003-2058-1263
National Central University · TW

Funding

Ministry of Science and Technology, Taiwan MOST 108-2221-E-008-081-MY3
6 · The paper itself

Abstract

Fall accidents can cause severe impacts on the physical health and the quality of life of those who suffer limb diseases or injuries, the elderly, and their caregivers. Moreover, the later the accident is discovered, the lower the chance of recovery of the injured one. In order to detect accidents earlier, we propose a data-driven human fall detection framework. By combining the sensing mechanism of a commercialized webcam and an ultrasonic sensor array, we develop a probability model for automatic human fall monitoring. The webcam and ultrasonic array respectively collect the transverse and longitudinal time-series signals from a moving subject, and then these signals are assembled as a three-dimensional (3D) movement trajectory map. We also use two different detection-tracking algorithms for recognizing the tracked subjects. The mean height of the subjects is 164.2 ± 12 cm. Based on the data density functional theory (DDFT), we use the 3D motion data to estimate the cluster numbers and their cluster boundaries. We also employ the Gaussian mixture model as the DDFT kernel. Then, we utilize those features to build a probabilistic model of human falling. The model visually exhibits three possible states of human motions: normal motion, transition, and falling. The acceptable detection accuracy and the small model size reveals the feasibility of the proposed hybridized platform. The time from starting the alarm to an actual fall is on average about 0.7 s in our platform. The proposed sensing mechanisms offer 90% accuracy, 90% sensitivity, and 95% precision in the data validation. Then these vital results validate that the proposed framework has comparable performance to the contemporary methods.

Indexed as

data density functional theoryfall detectionmachine learningposture detectionsensor fusionultrasonic sensors

Identifiers

PMID34062903
PMCPMC8147365
OpenAlexW3159122883

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.