Trial reportJAMA2021
Effect of Implantable vs Prolonged External Electrocardiographic Monitoring on Atrial Fibrillation Detection in Patients With Ischemic Stroke: The PER DIEM Randomized Clinical Trial.
Trial report in JAMA, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02428140 (Post-Embolic Rhythm Detection With Implantable Versus External Monitoring), which is not on this map. Cited by 87 papers, 9 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Post-Embolic Rhythm Detection With Implantable Versus External Monitoring: Pilot and Feasibility Study
Who cites it
87 citing papers in PubMed, 9 syntheses or guidelines pooled it, 161 citations in OpenAlex.
- Value of implantable loop recorders in detecting atrial fibrillation for stroke prevention: a systematic review and meta-analysis.Open heart · 2025Pooled it
- 2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines.Journal of the American College of Cardiology · 2024Guideline
- Guideline
- Prolonged cardiac monitoring for stroke prevention: A systematic review and meta-analysis of randomized-controlled clinical trials.European stroke journal · 2023Pooled it
- Effect of implantable cardiac monitors on preventing stroke: A systematic review and meta-analysis of randomized clinical trials.PloS one · 2023Pooled it
- How often is occult atrial fibrillation in cryptogenic stroke causal vs. incidental? A meta-analysis.Frontiers in neurology · 2023Pooled it
- Association between implantable loop recorder use and secondary stroke prevention: a meta-analysis.Open heart · 2022Pooled it
- The efficacy and safety of insertable cardiac monitor on atrial fibrillation detection in patients with ischemic stroke: a systematic review and meta-analysis.Journal of neurology · 2022Pooled it
- Meta-Analysis of Randomized Clinical Trials Comparing the Impact of Implantable Loop Recorder Versus Usual Care After Ischemic Stroke for Detection of Atrial Fibrillation and Stroke Risk.The American journal of cardiology · 2022Pooled it
- Echocardiographic Parameters for Predicting Atrial Fibrillation Following Ischemic Stroke: The PER DIEM Echocardiography Substudy.Echocardiography (Mount Kisco, N.Y.) · 2026Trial
- Recurrent atrial arrhythmia in a randomised controlled trial comparing contact force-guided and contact force-blinded ablation for typical atrial flutter.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022Trial
- Identifying patients at low risk for atrial fibrillation after cryptogenic stroke: the PAVA score.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Observational
- Timing of insertable cardiac monitor implantation after embolic stroke of undetermined source and its impact on atrial fibrillation detection: A target trial emulation analysis.International journal of stroke : official journal of the International Stroke Society · 2026Observational
- The PAFIS score for risk stratification of atrial fibrillation detected after stroke: a multicenter cohort study.International journal of cardiology. Heart & vasculature · 2026Article
- Comparative Efficacy of Continuous Versus Patch ECG Monitoring in Detecting Atrial Fibrillation Recurrence Post Catheter Ablation: Insights From the REAL-AF Registry.Journal of cardiovascular electrophysiology · 2026Observational
- Subdermal Insertable Sensors for Health Monitoring: Applications, Challenges, and Emerging Technologies.Annals of biomedical engineering · 2026Review
- Implantable Cardiac Monitoring for Atrial Fibrillation Detection in Patients with Stroke: A Systematic Review and Meta-Analysis.NeuroSci · 2026Review
- A randomized controlled trial of remote monitoring for cardiac implantable loop recorders: stay-away trial.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026Article
- Article
- Article
27 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
22 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: The relative rates of detection of atrial fibrillation (AF) or atrial flutter from evaluating patients with prolonged electrocardiographic monitoring with an external loop recorder or implantable loop recorder after an ischemic stroke are unknown. Objective: To determine, in patients with a recent ischemic stroke, whether 12 months of implantable loop recorder monitoring detects more occurrences of AF compared with conventional external loop recorder monitoring for 30 days. Design, Setting, and Participants: Investigator-initiated, open-label, randomized clinical trial conducted at 2 university hospitals and 1 community hospital in Alberta, Canada, including 300 patients within 6 months of ischemic stroke and without known AF from May 2015 through November 2017; final follow-up was in December 2018. Interventions: Participants were randomly assigned 1:1 to prolonged electrocardiographic monitoring with either an implantable loop recorder (n = 150) or an external loop recorder (n = 150) with follow-up visits at 30 days, 6 months, and 12 months. Main Outcomes and Measures: The primary outcome was the development of definite AF or highly probable AF (adjudicated new AF lasting ≥2 minutes within 12 months of randomization). There were 8 prespecified secondary outcomes including time to event analysis of new AF, recurrent ischemic stroke, intracerebral hemorrhage, death, and device-related serious adverse events within 12 months. Results: Among the 300 patients who were randomized (median age, 64.1 years [interquartile range, 56.1 to 73.7 years]; 121 were women [40.3%]; and 66.3% had a stroke of undetermined etiology with a median CHA2DS2-VASc [congestive heart failure, hypertension, age ≥75 years, diabetes, stroke or transient ischemic attack, vascular disease, age 65 to 74 years, sex category] score of 4 [interquartile range, 3 to 5]), 273 (91.0%) completed cardiac monitoring lasting 24 hours or longer and 259 (86.3%) completed both the assigned monitoring and 12-month follow-up visit. The primary outcome was observed in 15.3% (23/150) of patients in the implantable loop recorder group and 4.7% (7/150) of patients in the external loop recorder group (between-group difference, 10.7% [95% CI, 4.0% to 17.3%]; risk ratio, 3.29 [95% CI, 1.45 to 7.42]; P = .003). Of the 8 specified secondary outcomes, 6 were not significantly different. There were 5 patients (3.3%) in the implantable loop recorder group who had recurrent ischemic stroke vs 8 patients (5.3%) in the external loop recorder group (between-group difference, -2.0% [95% CI, -6.6% to 2.6%]), 1 (0.7%) vs 1 (0.7%), respectively, who had intracerebral hemorrhage (between-group difference, 0% [95% CI, -1.8% to 1.8%]), 3 (2.0%) vs 3 (2.0%) who died (between-group difference, 0% [95% CI, -3.2% to 3.2%]), and 1 (0.7%) vs 0 (0%) who had device-related serious adverse events. Conclusions and Relevance: Among patients with ischemic stroke and no prior evidence of AF, implantable electrocardiographic monitoring for 12 months, compared with prolonged external monitoring for 30 days, resulted in a significantly greater proportion of patients with AF detected over 12 months. Further research is needed to compare clinical outcomes associated with these monitoring strategies and relative cost-effectiveness. Trial Registration: ClinicalTrials.gov Identifier: NCT02428140.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.