Evidence map›Paper›PMID 34059754›Full record

ArticleScientific reports2021

Novel electronic biosensor for automated inoculum preparation to accelerate antimicrobial susceptibility testing.

Suzanne Putney, Andrew H Theiss, Nitin K Rajan, Eszter Deak, Creighton Buie, Yvonne Ngo, Hima Shah, Victoria Yuan, Elizabeth Botbol-Ponte, Adrian Hoyos-Urias and 4 more

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Suzanne Putney *Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Andrew H Theiss *Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Nitin K RajanAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Eszter DeakAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Creighton BuieAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Yvonne NgoAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Hima ShahAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Victoria YuanAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Elizabeth Botbol-PonteAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Adrian Hoyos-UriasAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Oren KnopfmacherAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
Catherine A HoganStanford University School of Medicine, 3375 Hillview Ave, Palo Alto, CA, 94304, USA.
Niaz BanaeiStanford University School of Medicine, 3375 Hillview Ave, Palo Alto, CA, 94304, USA.
Meike S HergetAvails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA. mherget@availsmedical.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A key predictor of morbidity and mortality for patients with a bloodstream infection is time to appropriate antimicrobial therapy. Accelerating antimicrobial susceptibility testing from positive blood cultures is therefore key to improving patient outcomes, yet traditional laboratory approaches can require 2-4 days for actionable results. The eQUANT-a novel instrument utilizing electrical biosensors-produces a standardized inoculum equivalent to a 0.5 McFarland directly from positive blood cultures. This proof-of-concept study demonstrates that eQUANT inocula prepared from clinically significant species of Enterobacterales were comparable to 0.5 McF inocula generated from bacterial colonies in both CFU/ml concentration and performance in antimicrobial susceptibility testing, with ≥ 95% essential and categorical agreement for VITEK2 and disk diffusion. The eQUANT, combined with a rapid, direct from positive blood culture identification technique, can allow the clinical laboratory to begin antimicrobial susceptibility testing using a standardized inoculum approximately 2-3 h after a blood culture flags positive. This has the potential to improve clinical practice by accelerating conventional antimicrobial susceptibility testing and the resulting targeted antibiotic therapy.

Indexed as

ElectronicsAlgorithmsAutomationBiosensing TechniquesColony Count, MicrobialEvaluation Studies as TopicFeasibility StudiesMicrobial Sensitivity TestsProof of Concept Study

Identifiers

PMID34059754
PMCPMC8166823

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.