ArticleScientific reports2021
Electromechanical impedance based self-diagnosis of piezoelectric smart structure using principal component analysis and LibSVM.
Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Real-time concrete strength monitoring using piezoelectric sensors and deep learning.Nature communications · 2025Article
- Smart monitoring of composite concrete damage using EMI technique with temperature effects compensation and ANN integration.Scientific reports · 2025Article
- In situ strength assessment of rapid set concrete in real time using resonant peak parameters of embedded PZT transducers.Scientific reports · 2025Article
- An Efficient Procedure for Bonding Piezoelectric Transducers to Thermoplastic Composite Structures for SHM Application and Its Durability in Aeronautical Environmental Conditions.Sensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The long-term use of a piezoelectric smart structure make it difficult to judge whether the structure or piezoelectric lead zirconate titanate (PZT) is damaged when the signal changes. If the sensor fault occurs, the cases and degrees of the fault are unknown based on the electromechanical impedance method. Therefore, after the principal component analysis (PCA) of six characteristic indexes, a two-component solution that could explain 99.2% of the variance in the original indexes was obtained to judge whether the damage comes from the PZT. Then LibSVM was used to make an effective identification of four sensor faults (pseudo soldering, debonding, wear, and breakage) and their three damage degrees. The result shows that the identification accuracy of damaged PZT reached 97.5%. The absolute scores of PCA comprehensive evaluation for structural damages are less than 0.5 while for sensor faults are greater than 0.6. By comparing the scores of the samples under unknown conditions with the set threshold, whether the sensor faults occur is effectively judged; the intact and 12 possible damage states of PZT can be all classified correctly with the model trained by LibSVM. It is feasible to use LibSVM to classify the cases and degrees of sensor faults.