Evidence map›Paper›PMID 34059704›Full record

ArticleScientific reports2021

Electromechanical impedance based self-diagnosis of piezoelectric smart structure using principal component analysis and LibSVM.

Xie Jiang, Xin Zhang, Tao Tang, Yuxiang Zhang

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Xie JiangXi'an Research Inst. of Hi-Tech, Xi'an, 710025, China.
Xin ZhangXi'an Research Inst. of Hi-Tech, Xi'an, 710025, China.
Tao TangXi'an Research Inst. of Hi-Tech, Xi'an, 710025, China.
Yuxiang ZhangXi'an Research Inst. of Hi-Tech, Xi'an, 710025, China. sxbbm201601@126.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The long-term use of a piezoelectric smart structure make it difficult to judge whether the structure or piezoelectric lead zirconate titanate (PZT) is damaged when the signal changes. If the sensor fault occurs, the cases and degrees of the fault are unknown based on the electromechanical impedance method. Therefore, after the principal component analysis (PCA) of six characteristic indexes, a two-component solution that could explain 99.2% of the variance in the original indexes was obtained to judge whether the damage comes from the PZT. Then LibSVM was used to make an effective identification of four sensor faults (pseudo soldering, debonding, wear, and breakage) and their three damage degrees. The result shows that the identification accuracy of damaged PZT reached 97.5%. The absolute scores of PCA comprehensive evaluation for structural damages are less than 0.5 while for sensor faults are greater than 0.6. By comparing the scores of the samples under unknown conditions with the set threshold, whether the sensor faults occur is effectively judged; the intact and 12 possible damage states of PZT can be all classified correctly with the model trained by LibSVM. It is feasible to use LibSVM to classify the cases and degrees of sensor faults.

Identifiers

PMID34059704
PMCPMC8167124

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.