Evidence map›Paper›PMID 34056312›Full record

ArticleACS omega2021

Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood.

Elsi Verrinder, Niklas Wester, Elli Leppänen, Tuomas Lilius, Eija Kalso, Bjo Rn Mikladal, Ilkka Varjos, Jari Koskinen, Tomi Laurila

Abstract read
In one paragraph

Article in ACS omega, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Elsi VerrinderDepartment of Electrical Engineering and Automation, Aalto University, Tietotie 3, Espoo 02150, Finland.ORCID 0000-0002-5847-7296
Niklas WesterDepartment of Chemistry and Materials Science, Aalto University, Kemistintie 1, Espoo 02150, Finland.ORCID 0000-0002-7937-9011
Elli LeppänenDepartment of Electrical Engineering and Automation, Aalto University, Tietotie 3, Espoo 02150, Finland.
Tuomas LiliusDepartment of Pharmacology, University of Helsinki, Haartmaninkatu 8, Helsinki 00290, Finland.
Eija KalsoDepartment of Pharmacology, University of Helsinki, Haartmaninkatu 8, Helsinki 00290, Finland.
Bjo Rn MikladalCanatu Oy, Tiilenlyöjänkuja 9, Vantaa 01720, Finland.
Ilkka VarjosCanatu Oy, Tiilenlyöjänkuja 9, Vantaa 01720, Finland.
Jari KoskinenDepartment of Chemistry and Materials Science, Aalto University, Kemistintie 1, Espoo 02150, Finland.
Tomi LaurilaDepartment of Electrical Engineering and Automation, Aalto University, Tietotie 3, Espoo 02150, Finland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible sensor strips with integrated reference and counter electrodes, compatible with industrial-scale processes. A thin Nafion coating was used on top of the sensors to enable direct electrochemical detection in whole blood. These sensors were shown to detect clinically relevant concentrations of morphine both in buffer and in whole blood samples. Small 38 μL finger-prick blood samples were spiked with 2 μL of morphine solution of several concentrations and measured without precipitation of proteins or any other further pretreatment. A linear range of 0.5-10 μM was achieved in both matrices and a detection limit of 0.48 μM in buffer. In addition, to demonstrate the applicability of the sensor in a point-of-care device, single-determination measurements were done with capillary samples from three subjects. An average recovery of 60% was found, suggesting that the sensor only measures the free, unbound fraction of the drug. An interference study with other opioids and possible interferents showed the selectivity of the sensor. This study clearly indicates that these Nafion/SWCNT sensor strips show great promise as a point-of-care rapid test for morphine in blood.

Identifiers

PMID34056312
PMCPMC8154029

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked