Evidence map›Paper›PMID 34050945›Full record

ArticleJournal of medical virology2021

Efficacy comparison of three rapid antigen tests for SARS-CoV-2 and how viral load impact their performance.

Laurent Blairon, Roberto Cupaiolo, Isabelle Thomas, Sébastien Piteüs, Alain Wilmet, Ingrid Beukinga, Marie Tré-Hardy

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in Journal of medical virology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 4 pooled it
1.8field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 4 syntheses or guidelines pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection.The Cochrane database of systematic reviews · 2022
    Pooled it
  4. Pooled it
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Laurent BlaironLaboratory Medicine, Iris Hospitals South, Brussels, Belgium.ORCID http://orcid.org/0000-0003-0304-7624
Roberto CupaioloLaboratory Medicine, Iris Hospitals South, Brussels, Belgium.
Isabelle ThomasDepartment of Virology, Sciensano, Brussels, Belgium.
Sébastien PiteüsLaboratory Medicine, Iris Hospitals South, Brussels, Belgium.
Alain WilmetLaboratory Medicine, Iris Hospitals South, Brussels, Belgium.
Ingrid BeukingaLaboratory Medicine, Iris Hospitals South, Brussels, Belgium.
Marie Tré-HardyLaboratory Medicine, Iris Hospitals South, Brussels, Belgium.ORCID http://orcid.org/0000-0003-4915-1339
Hôpitaux Iris Sud · BESciensano (Belgium) · BEUniversité Libre de Bruxelles · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

More and more rapid antigen tests for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) appear in the market with varying performance. The sensitivity of these tests heavily depends on the viral load, extrapolated by the threshold cycle (Ct). It is therefore essential to verify their performance before their inclusion in routine. The Coronavirus Ag Rapid Test Cassette Bio-Rad, the GSD NovaGen SARS-CoV-2 (COVID-19) Antigen Rapid Test, and the Aegle Coronavirus Ag Rapid Test Cassette were evaluated on 199 samples: 150 fresh samples from the routine and positive in quantitative reverse-transcription polymerase chain reaction (RT-qPCR), nine fresh samples negative in RT-qPCR, and 40 frozen samples, taken before the discovery of SARS-CoV-2 but positive for other respiratory viruses. Positive RT-qPCR samples were categorized according to their Ct: Ct < 20 (18.7%), ≥ 20-< 25 (27.3%), ≥ 25-< 30 (18.7%), ≥ 30-35 (17.3%), and > 35 (18.0%). Sensitivities (95% confidence interval) for Ct below 25 were 95.7% (92.4-98.9), 97.1% (94.4-99.8), and 97.1% (94.4-99.8) for GSD NovaGen, Bio-Rad, and Aegle, respectively but drastically dropped when Ct exceeded 27. Among samples with previously diagnosed viruses, seven false-positive results were found with GSD NovaGen only (specificity 85.7%). Equivalent, high sensitivities were observed with the highest viral load samples. The GSD NovaGen assay showed less specificity. Although the three kits tested in this study are inadequate for routine testing in a high throughput laboratory, they can help to quickly identify the most infectious patients and screen their close contacts in an environment where molecular tests are not readily available.

Indexed as

COVID-19 Serological TestingPoint-of-Care TestingViral LoadAntigens, ViralCOVID-19COVID-19 Nucleic Acid TestingHumansRNA, ViralSARS-CoV-2Sensitivity and SpecificityAntigens, ViralRNA, ViralCOVID-19point-of-care testingrapid antigen testSARS-CoV-2

Identifiers

PMID34050945
PMCPMC8242364
OpenAlexW3164716913

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.