SynthesisThe Cochrane database of systematic reviews2021
Mesh fixation techniques in primary ventral or incisional hernia repair.
Synthesis in The Cochrane database of systematic reviews, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 4 syntheses or guidelines pooled it, 36 citations in OpenAlex.
- A comparative study in elective repair of large incisional hernias using on-lay mesh vs. sub-lay mesh: a meta-analysis.Updates in surgery · 2024Pooled it
- Comparative effectiveness of hybrid and laparoscopic techniques for repairing complex incisional ventral hernias: a systematic review and meta-analysis.BMC surgery · 2023Pooled it
- Laparoscopic treatment of ventral hernias: the Italian national guidelines.Updates in surgery · 2023Guideline
- Mesh fixation techniques in primary ventral or incisional hernia repair.The Cochrane database of systematic reviews · 2021Pooled it
- Robotic-assisted compared with laparoscopic incisional hernia repair following oncologic surgery: short- and long-term outcomes of a randomized controlled trial.Journal of robotic surgery · 2023Trial
- The effect of surgical approach on opioid prescription rates for outpatient ventral hernia repair.Hernia : the journal of hernias and abdominal wall surgery · 2026Article
- Article
- Is biological mesh a suitable option for laparoscopic intraperitoneal onlay mesh plus (IPOM plus) repair in the treatment of abdominal wall hernias?BMC surgery · 2025Article
- Article
- Anterolateral thigh flap combined with free fascia lata graft for an adult abdominal wall defect reconstruction: a special case report.Frontiers in surgery · 2025Article
- Ventral hernia repair in India: a Delphi consensus.Hernia : the journal of hernias and abdominal wall surgery · 2024Review
- Retrorectus Ventral Hernia Repair Utilizing T-line Hernia Mesh: Technical Descriptions.Plastic and reconstructive surgery. Global open · 2024Article
- Exploring Variable Approaches in Complex Hernia Repair: A Comprehensive Literature Review.Cureus · 2024Review
- Laparoscopic Intraperitoneal Onlay Mesh (IPOM) in the Treatment of Ventral Hernias: Technique Discussion Points.Cureus · 2024Review
- Laparoscopic versus hybrid approach for treatment of incisional ventral hernia: a 5-10-year follow-up of the randomized controlled multicenter study.Hernia : the journal of hernias and abdominal wall surgery · 2024Article
- Review
- Primary Ventral Hernia Repair and the Risk of Postoperative Small Bowel Obstruction: Intra Versus Extraperitoneal Mesh.Journal of clinical medicine · 2023Article
- Primary Lumbar Hernia, Review and Proposals for a Standardized Treatment.Journal of abdominal wall surgery : JAWS · 2023Article
- Comparative review of outcomes: single-incision laparoscopic total extra-peritoneal sub-lay (SIL-TES) mesh repair versus laparoscopic intraperitoneal onlay mesh (IPOM) repair for ventral hernia.Updates in surgery · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe use of a mesh in primary ventral or incisional hernia repair lowers the recurrence rate and is the accepted standard of care for larger defects. In laparoscopic primary ventral or incisional hernia repair the insertion of a mesh is indispensable. Different mesh fixation techniques have been used and refined over the years. The type of fixation technique is claimed to have a major impact on recurrence rates, chronic pain, health-related quality of life (HRQOL) and complication rates.
objectivesTo determine the impact of different mesh fixation techniques for primary and incisional ventral hernia repair on hernia recurrence, chronic pain, HRQOL and complications. SEARCH
methodsOn 2 October 2020 we searched CENTRAL, MEDLINE (Ovid MEDLINE(R)) Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Ovid MEDLINE(R) Daily and Ovid MEDLINE(R)), Ovid Embase, and two trials registries. We also performed handsearches, and contacted experts from the European Hernia Society (EHS). SELECTION CRITERIA: We included randomised controlled trials (RCTs) including adults with primary ventral or incisional hernia that compared different types of mesh fixation techniques (absorbable/nonabsorbable sutures, absorbable/nonabsorbable tacks, fibrin glue, and combinations of these techniques). DATA COLLECTION AND ANALYSIS: We extracted data in standardised piloted tables, or if necessary, directly into Review Manager 5. We assessed risks of bias with the Cochrane 'Risk of bias' tool. Two review authors independently selected the publications, and extracted data on results. We calculated risk ratios (RRs) for binary outcomes and mean differences (MDs) for continuous outcomes. For pooling we used an inverse-variance random-effects meta-analysis or the Peto method in the case of rare events. We prepared GRADE 'Summary of findings' tables. For laparoscopic repair we considered absorbable tacks compared to nonabsorbable tacks, and nonabsorbable tacks compared to nonabsorbable sutures as key comparisons. MAIN
resultsWe included 10 trials with a total of 787 participants. The number of randomised participants ranged from 40 to 199 per comparison. Eight studies included participants with both primary and incisional ventral hernia. One study included only participants with umbilical hernia, and another only participants with incisional hernia. Hernia size varied between studies. We judged the risk of bias as moderate to high. Absorbable tacks compared to nonabsorbable tacks Recurrence rates in the groups were similar (RR 0.74, 95% confidence interval (CI) 0.17 to 3.22; 2 studies, 101 participants). It is uncertain whether there is a difference between absorbable tacks and nonabsorbable tacks in recurrence because the certainty of evidence was very low. Evidence suggests that the difference between groups in early postoperative, late follow-up, chronic pain and HRQOL is negligible. Nonabsorbable tacks compared to nonabsorbable sutures At six months there was one recurrence in each group (RR 1.00, 95% CI 0.07 to 14.79; 1 study, 36 participants). It is uncertain whether there is a difference between nonabsorbable tacks and nonabsorbable sutures in recurrence because the certainty of evidence was very low. Evidence suggests that the difference between groups in early postoperative, late follow-up and chronic pain is negligible. We found no study that assessed HRQOL. Absorbable tacks compared to absorbable sutures No recurrence was observed at one year (very low certainty of evidence). Early postoperative pain was higher in the tacks group (VAS 0 - 10: MD -2.70, 95% CI -6.67 to 1.27; 1 study, 48 participants). It is uncertain whether there is a difference between absorbable tacks compared to absorbable sutures in early postoperative pain because the certainty of evidence was very low. The MD for late follow-up pain was -0.30 (95% CI -0.74 to 0.14; 1 study, 48 participants). We found no study that assessed HRQOL. Combination of different fixation types (tacks and sutures) or materials (absorbable and nonabsorbable) There were mostly negligible or only small differences between combinations (e.g. tacks plus sutures) compared to a single technique (e.g. sutures only), as well as combinations compared to other combinations (e.g. absorbable sutures combined with nonabsorbable sutures compared to absorbable tacks combined with nonabsorbable tacks) in all outcomes. It is uncertain whether there is an advantage for combining different fixation types or materials for recurrence, chronic pain, HRQOL and complications, because the evidence certainty was very low or low, or we found no study on important outcomes. Nonabsorbable tacks compared to fibrin sealant The two studies showed different directions of effects: one showed higher rates for nonabsorbable tacks, and the other showed higher rates for fibrin sealant. Low-certainty evidence suggests that the difference between groups in early postoperative, late follow-up, chronic pain and HRQOL is negligible. Absorbable tacks compared to fibrin sealant One recurrence in the tacks group and none in the fibrin sealant group were noted after one year (low certainty of evidence). Early postoperative pain might be slightly lower using tacks (VAS 0 - 100; MD -12.40, 95% CI -27.60 to, 2.80;1 study, 50 participants; low-certainty evidence). The pattern of pain and HRQOL course over time (up to 1 year) was similar in the groups (low certainty of evidence). AUTHORS'
conclusionsCurrently none of the techniques can be considered superior to any other, because the certainty of evidence was low or very low for all outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.