ArticleBioMed research international2021
Effects and Anti-rotation Stabilization of the Non-bridging External Fixation for Pronation-Abduction Stage III Ankle Fracture: A Cadaveric Study.
Article in BioMed research international, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThis study is aimed at providing a nonbridging external fixation technique with pinning fixation for the pronation-abduction stage III ankle fracture. The secondary purpose was to evaluate its effect on anatomic reduction and fracture fragment stability against cadaveric models' rotation.
methodA paired design study was conducted using 14 pairs of the cadaveric model which had been modeled for pronation-abduction stage III ankle fracture. One fracture model from each pair was randomly allocated to receive an open reduction and internal fixation, while the other was reduced and stabilized with the external fixation technique. After the surgery, the antirotational stability tests were performed with external rotation torques of 10 nm, 15 nm, and 20 nm applied, respectively. The postoperation reduction rate and ankle parameters were recorded in anteroposterior and lateral radiographs before and after the antirotational stability experiment.
resultThe outcomes were assessed according to Burwell-Charnley's radiographic criteria of reduction. It showed no statistically significant differences in reduction between the two groups (
conclusionThis nonbridging external fixation method with pin fixation of fracture fragments might have the same effect as that of internal fixation on the reduction rate of pronation-abduction stage III ankle fracture.