Evidence map›Paper›PMID 34045782›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2019

A Spherical Mirror-based Illumination System for Fluorescence Excitation-Scanning Hyperspectral Imaging.

Samantha Gunn Mayes, Samuel A Mayes, Craig Browning, Marina Parker, Thomas C Rich, Silas J Leavesley

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Spectral Illumination System Utilizing Spherical Reflection Optics.Proceedings of SPIE--the International Society for Optical Engineering · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Samantha Gunn MayesDepartment of Chemical and Biomolecular Engineering.
Samuel A MayesDepartment of Chemical and Biomolecular Engineering.
Craig BrowningDepartment of Chemical and Biomolecular Engineering.
Marina ParkerDepartment of Chemical and Biomolecular Engineering.
Thomas C RichDepartment of Pharmacology.
Silas J LeavesleyDepartment of Chemical and Biomolecular Engineering.
University of South Alabama · US

Funding

T-type Calcium Channels and von Willebrand Factor ReleaseP01HL066299 · NHLBI · UNIVERSITY OF SOUTH ALABAMA · PI ALVAREZ, DIEGO F. · 2001 to 2022
$34.6M
Functional Diversity of Compartmentalized Calcium Signaling in Airway Smooth MuscleR01HL137030 · NHLBI · THOMAS JEFFERSON UNIVERSITY · PI DESHPANDE, DEEPAK A · 2018 to 2021
$2.2M
NHLBI NIH HHS P01 HL066299NHLBI NIH HHS R01 HL137030
6 · The paper itself

Abstract

Many hardware approaches have been developed for implementing hyperspectral imaging on fluorescence microscope systems; each with tradeoffs in spectral sensitivity and spectral, spatial, and temporal sampling. For example, tunable filter-based systems typically have limited wavelength switching speeds and sensitivities that preclude high-speed spectral imaging. Here, we present a novel approach combining multiple illumination wavelengths using solid state LEDs in a 2-mirror configuration similar to a Cassegrain reflector assembly. This approach provides spectral discrimination by scanning a range of fluorescence excitation wavelengths, which we have previously shown can improve spectral image acquisition time compared to traditional fluorescence emission-scanning hyperspectral imaging. In this work, the geometry of the LED and other optical components was optimized. A model of the spectral illuminator was designed using TracePro ray tracing software (Lambda Research Corp.) that included an emitter, lens, Spherical mirror, flat mirror, and liquid light guide input. A parametric sensitivity study was performed to optimize the optical throughput varying the LED viewing angle, properties of the Spherical reflectors, the lens configuration, focal length, and position. The following factors significantly affected the optical throughput: LED viewing angle, lens position, and lens focal length. Several types of configurations were evaluated, and an optimized lens and LED position were determined. Initial optimization results indicate that a 10% optical transmission can be achieved for either a 16 or 32 wavelength system. Future work will include continuing to optimize the ray trace model, prototyping, and experimental testing of the optimized configuration.

Indexed as

BioimagingFluorescenceHSIImagingMicroscopeMicroscopySpectralSpectroscopy

Identifiers

PMID34045782
PMCPMC8151156
OpenAlexW2919079835

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.