Evidence map›Paper›PMID 34040290›Full record

ArticleIndian journal of nuclear medicine : IJNM : the official journal of the Society of Nuclear Medicine, India

Optimization of Ordered Subset Expectation Maximization Parameters for Image Reconstruction in Tc-99m Methoxyisobutylisonitrile Myocardial Perfusion SPECT and Comparison with Corresponding Filtered Back Projection-Reconstructed Images.

Pankaj Dheer, Priyanka Gupta, Sameer Kamalakar Taywade, Averilicia Passah, Anil Kumar Pandey, Chetan Patel

Abstract read
In one paragraph

Article in Indian journal of nuclear medicine : IJNM : the official journal of the Society of Nuclear Medicine, India. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pankaj DheerDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Priyanka GuptaDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Sameer Kamalakar TaywadeDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Averilicia PassahDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Anil Kumar PandeyDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Chetan PatelDepartment of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purpose of the studyTo establish the most appropriate ordered subset expectation maximization (OSEM) parameters for image reconstruction in Tc-99m methoxyisobutylisonitrile (MIBI) myocardial perfusion SPECT (MPS) and comparison with corresponding filtered back projection (FBP)-reconstructed images.

methodsA total of 99 stress-rest MPS studies (47 normal and 52 abnormal) were retrospectively analyzed using 16 different combinations of iterations and subsets. Images were reconstructed both with and without postreconstruction Butterworth filter (cutoff frequency and order for stress: 0.4 and 10 and for rest: 0.52 and 5, respectively) for each combination. A total of 3168 images were evaluated qualitatively by two nuclear medicine physicians on a scoring scale of 1-4. Best visual quality image iteration-subset combination was determined for each patient both with and without Butterworth filter and was further compared with FBP-reconstructed image. The interobserver agreement was obtained using kappa statistics.

resultsThe best quality images were obtained using a combination of four iterations and six subsets for both with and without Butterworth filter. The value of kappa for interobserver agreement for OSEM images with Butterworth filter was 0.570 and for OSEM images without Butterworth filter was 0.857. On comparison, FBP images were better than OSEM-reconstructed images without Butterworth filter (

conclusionThe most appropriate OSEM reconstruction parameter in Tc-99m MIBI MPS is 4-iteration and 6-subset combination. FBP-reconstructed images were better than the images reconstructed with OSEM without postreconstruction Butterworth filter. However, OSEM-reconstructed image with Butterworth filter was better than FBP images.

Indexed as

Filtered back projectionimage reconstructionmyocardial perfusion SPECTordered subset expectation maximization

Identifiers

PMID34040290
PMCPMC8130694

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.