Evidence map›Paper›PMID 34035325›Full record

ArticleScientific reports2021

Personalized intervention cardiology with transcatheter aortic valve replacement made possible with a non-invasive monitoring and diagnostic framework.

Seyedvahid Khodaei, Alison Henstock, Reza Sadeghi, Stephanie Sellers, Philipp Blanke, Jonathon Leipsic, Ali Emadi, Zahra Keshavarz-Motamed

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Seyedvahid KhodaeiDepartment of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada.
Alison HenstockDepartment of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada.
Reza SadeghiDepartment of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada.
Stephanie SellersSt. Paul's Hospital, Vancouver, BC, Canada.
Philipp BlankeSt. Paul's Hospital, Vancouver, BC, Canada.
Jonathon LeipsicSt. Paul's Hospital, Vancouver, BC, Canada.
Ali EmadiDepartment of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada.
Zahra Keshavarz-MotamedDepartment of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada. motamedz@mcmaster.ca.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One of the most common acute and chronic cardiovascular disease conditions is aortic stenosis, a disease in which the aortic valve is damaged and can no longer function properly. Moreover, aortic stenosis commonly exists in combination with other conditions causing so many patients suffer from the most general and fundamentally challenging condition: complex valvular, ventricular and vascular disease (C3VD). Transcatheter aortic valve replacement (TAVR) is a new less invasive intervention and is a growing alternative for patients with aortic stenosis. Although blood flow quantification is critical for accurate and early diagnosis of C3VD in both pre and post-TAVR, proper diagnostic methods are still lacking because the fluid-dynamics methods that can be used as engines of new diagnostic tools are not well developed yet. Despite remarkable advances in medical imaging, imaging on its own is not enough to quantify the blood flow effectively. Moreover, understanding of C3VD in both pre and post-TAVR and its progression has been hindered by the absence of a proper non-invasive tool for the assessment of the cardiovascular function. To enable the development of new non-invasive diagnostic methods, we developed an innovative image-based patient-specific computational fluid dynamics framework for patients with C3VD who undergo TAVR to quantify metrics of: (1) global circulatory function; (2) global cardiac function as well as (3) local cardiac fluid dynamics. This framework is based on an innovative non-invasive Doppler-based patient-specific lumped-parameter algorithm and a 3-D strongly-coupled fluid-solid interaction. We validated the framework against clinical cardiac catheterization and Doppler echocardiographic measurements and demonstrated its diagnostic utility by providing novel analyses and interpretations of clinical data in eleven C3VD patients in pre and post-TAVR status. Our findings position this framework as a promising new non-invasive diagnostic tool that can provide blood flow metrics while posing no risk to the patient. The diagnostic information, that the framework can provide, is vitally needed to improve clinical outcomes, to assess patient risk and to plan treatment.

Indexed as

Aortic Valve StenosisBlood CirculationComputed Tomography AngiographyEarly DiagnosisEchocardiography, DopplerHumansPrecision MedicineRetrospective StudiesTranscatheter Aortic Valve ReplacementTreatment Outcome

Identifiers

PMID34035325
PMCPMC8149684

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.