Evidence map›Paper›PMID 34029188›Full record

ArticleIEEE transactions on medical imaging2021

Joint Design of RF and Gradient Waveforms via Auto-differentiation for 3D Tailored Excitation in MRI.

Tianrui Luo, Douglas C Noll, Jeffrey A Fessler, Jon-Fredrik Nielsen

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. The Ritz Adjoint Method for MRI Pulse Design.IEEE transactions on medical imaging · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tianrui Luo
Douglas C Noll
Jeffrey A Fessler
Jon-Fredrik Nielsen

Funding

Fast Functional MRI with Sparse Sampling and Model-Based ReconstructionR01EB023618 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI FESSLER, JEFFREY A, NOLL, DOUGLAS C · 2017 to 2020
$1.5M
Toward robust whole-brain 3D functional MRI at 3T with reduced signal loss artifactsR21AG061839 · NIA · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NIELSEN, JON-FREDRIK · 2019 to 2020
$408k
NIA NIH HHS R21 AG061839NIBIB NIH HHS R01 EB023618
6 · The paper itself

Abstract

This paper proposes a new method for joint design of radiofrequency (RF) and gradient waveforms in Magnetic Resonance Imaging (MRI), and applies it to the design of 3D spatially tailored saturation and inversion pulses. The joint design of both waveforms is characterized by the ODE Bloch equations, to which there is no known direct solution. Existing approaches therefore typically rely on simplified problem formulations based on, e.g., the small-tip approximation or constraining the gradient waveforms to particular shapes, and often apply only to specific objective functions for a narrow set of design goals (e.g., ignoring hardware constraints). This paper develops and exploits an auto-differentiable Bloch simulator to directly compute Jacobians of the (Bloch-simulated) excitation pattern with respect to RF and gradient waveforms. This approach is compatible with arbitrary sub-differentiable loss functions, and optimizes the RF and gradients directly without restricting the waveform shapes. For computational efficiency, we derive and implement explicit Bloch simulator Jacobians (approximately halving computation time and memory usage). To enforce hardware limits (peak RF, gradient, and slew rate), we use a change of variables that makes the 3D pulse design problem effectively unconstrained; we then optimize the resulting problem directly using the proposed auto-differentiation framework. We demonstrate our approach with two kinds of 3D excitation pulses that cannot be easily designed with conventional approaches: Outer-volume saturation (90° flip angle), and inner-volume inversion.

Indexed as

AlgorithmsMagnetic Resonance ImagingHeart RatePhantoms, ImagingRadio Waves

Identifiers

PMID34029188
PMCPMC8669750

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.