Evidence map›Paper›PMID 34025740›Full record

ArticleJournal of contemporary brachytherapy2021

Manufacturing and evaluation of multi-channel cylinder applicator with 3D printing technology.

Reza Mohammadi, Zahra Siavashpour, Seyed Rashid Hosseini Aghdam, Samar Fazli, Tibor Major, Ali Asghar Rohani

Abstract read
In one paragraph

Article in Journal of contemporary brachytherapy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. The value of brachytherapy in the age of advanced external beam radiotherapy: a review of the literature in terms of dosimetry.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Reza MohammadiDepartment of Medical Physics, Iran University of Medical Sciences, Tehran, Iran.
Zahra SiavashpourDepartment of Radiotherapy Oncology, Shohada-e Tajrish Educational Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Seyed Rashid Hosseini AghdamDepartment of Medical Radiation Engineering, Shahid Beheshti University, Tehran, Iran.
Samar FazliIRA Radiotherapy Center, National Center of Oncology V.A. Fanarjian Hospital, Yerevan, Armenia.
Tibor MajorDepartment of Oncology, Semmelweis University, Budapest, Hungary.
Ali Asghar RohaniDepartment of Medical Physics, Tehran University of Medical Sciences, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study was designed to assess dosimetric characteristics of 3D-printed personalized multi-channel cylinder applicator (MCCA). MATERIAL AND

methodsUnionTech RS Pro 600 (UnionTech, Inc., Shanghai, China) 3D printer was used for manufacturing MCCA. The geometry of MCCA was designed with Fusion 360 v.2.0.5827 (Autodesk, Inc.) software. The designed file was exported to Meshmixer v.3.5 (Autodesk, Inc.) to create three-dimensional model in stereolithography (STL) file format, which is the common file format for inputting data to 3D printers. We used high-temp resin, FLHTAM02 model (Formlabs Inc., MA, USA), as material in 3D printing process. This resin model has good resistance to high temperature and compatibility with various solvents. We created a simple cubic shape phantom for dosimetric evaluation of the applicator with Gafchromic EBT3 films. Also, Monte Carlo method was applied to simulate MCCA in the same configuration as in experimental test.

resultsThe mean ± standard deviation (SD) difference between measured and calculated doses in treatment planning system (TPS) for all control points was 0.0860 ±0.0393 Gy, corresponding to 4.01 ±1.21%. The mean ±SD difference between doses calculated by Monte Carlo simulation and TPS for all control points was 0.0996 ±0.0471 Gy, corresponding to 4.58 ±1.05%. The mean ±SD of dose difference between film measurement and Monte Carlo simulation for all control points was 0.0136 ±0.0200 Gy, corresponding to 0.60 ±0.69%.

conclusionsDosimetric results and mechanical accuracy of MCCA show that high-temp resin with SLA 3D printing technique can be used for producing patient-specific MCCA in brachytherapy.

Indexed as

3D printingbrachytherapycervical cancervaginal cancer

Identifiers

PMID34025740
PMCPMC8117717

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.