ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2021
A Surgical Robotic System for Treatment of Pelvic Osteolysis Using an FBG-Equipped Continuum Manipulator and Flexible Instruments.
Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 64 citations in OpenAlex.
- Interaction-aware dexterous robot for minimally invasive transcanal inner ear interventions.Nature communications · 2026Article
- A Synergistic Patient-Specific Approach for Enhanced Spinal Fixation Using a Novel Flexible Pedicle Screw and a Complementary Steerable Drilling Robotic System.IEEE transactions on bio-medical engineering · 2026Article
- A Biomechanics-Aware Robot-Assisted Steerable Drilling Framework for Minimally Invasive Spinal Fixation Procedures.IEEE transactions on bio-medical engineering · 2024Article
- Design and Fabrication of a Fiber Bragg Grating Shape Sensor for Shape Reconstruction of a Continuum Manipulator.IEEE sensors journal · 2023Article
- Simultaneous Shape and Tip Force Sensing for the COAST Guidewire Robot.IEEE robotics and automation letters · 2023Article
- A Surgical Robotic System for Osteoporotic Hip Augmentation: System Development and Experimental Evaluation.IEEE transactions on medical robotics and bionics · 2023Article
- A Dexterous Robotic System for Autonomous Debridement of Osteolytic Bone Lesions in Confined Spaces: Human Cadaver Studies.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2022Article
- Clinical and radiological outcomes of jumbo cup in revision total hip arthroplasty: A systematic review.Frontiers in surgery · 2022Review
- Fluoroscopic Navigation for a Surgical Robotic System Including a Continuum Manipulator.IEEE transactions on bio-medical engineering · 2022Article
- An Active Steering Hand-held Robotic System for Minimally Invasive Orthopaedic Surgery Using a Continuum Manipulator.IEEE robotics and automation letters · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
This paper presents the development and experimental evaluation of a redundant robotic system for the less-invasive treatment of osteolysis (bone degradation) behind the acetabular implant during total hip replacement revision surgery. The system comprises a rigid-link positioning robot and a Continuum Dexterous Manipulator (CDM) equipped with highly flexible debriding tools and a Fiber Bragg Grating (FBG)-based sensor. The robot and the continuum manipulator are controlled concurrently via an optimization-based framework using the Tip Position Estimation (TPE) from the FBG sensor as feedback. Performance of the system is evaluated on a setup that consists of an acetabular cup and saw-bone phantom simulating the bone behind the cup. Experiments consist of performing the surgical procedure on the simulated phantom setup. CDM TPE using FBGs, target location placement, cutting performance, and the concurrent control algorithm capability in achieving the desired tasks are evaluated. Mean and standard deviation of the CDM TPE from the FBG sensor and the robotic system are 0.50 mm, and 0.18 mm, respectively. Using the developed surgical system, accurate positioning and successful cutting of desired straight-line and curvilinear paths on saw-bone phantoms behind the cup with different densities are demonstrated. Compared to the conventional rigid tools, the workspace reach behind the acetabular cup is 2.47 times greater when using the developed robotic system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.