Evidence map›Paper›PMID 34023954›Full record

ArticleOdontology2021

Light and viscosity effects on the curing potential of bulk-fill composites placed in deep cavities.

Rodrigo Antonio Modena, Mário Alexandre Coelho Sinhoreti, William Palin, Larissa Maria Cavalcante, Luis Felipe Schneider

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Odontology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Rodrigo Antonio ModenaSchool of Dentistry, UFF-Universidade Federal Fluminense, Niterói, RJ, Brazil.ORCID http://orcid.org/0000-0001-9975-2330
Mário Alexandre Coelho SinhoretiDepartment of Restorative Dentistry, Dental Materials Division, Piracicaba School of Dentistry, UNICAMP-Universidade Estadual de Campinas, Piracicaba, SP, Brazil.ORCID http://orcid.org/0000-0002-1932-2902
William PalinBiomaterials Unit, School of Dentistry, College of Medical and Dental Sciences, Institute of Clinical Sciences, University of Birmingham, Birmingham, UK.ORCID http://orcid.org/0000-0003-2225-7635
Larissa Maria CavalcanteSchool of Dentistry, UFF-Universidade Federal Fluminense, Niterói, RJ, Brazil.ORCID http://orcid.org/0000-0001-8442-3497
Luis Felipe SchneiderSchool of Dentistry, UFF-Universidade Federal Fluminense, Niterói, RJ, Brazil. felipefop@gmail.com.ORCID http://orcid.org/0000-0002-7154-8845
Universidade Federal Fluminense · BRUniversidade Estadual de Campinas (UNICAMP) · BRUniversity of Birmingham · GB

Funding

CAPES MS1FAPERJ E-26/202.735/2018
6 · The paper itself

Abstract

To determine the influence of light curing units (LCUs) and material viscosity on the degree of conversion (DC) of bulk-fill (BF) resin-based composites (RBCs) placed in deep cavity preparations. Four LCUs were tested: Valo cordless, Bluephase-G2, Poly wireless and Radii-cal. Light irradiance was determined at 0 mm and 6 mm distance to the reading sensor. The following RBCs were considered: Filtek BF, Filtek BF Flow, Opus BF, Opus BF Flow, Tetric N-Ceram BF and Surefil SDR Flow. Sirius-Z was used with the incremental technique. DC (n = 3) was evaluated by spectroscopy both at top and bottom regions of deep preparations with 6 mm depth. The data were submitted to ANOVA and Tukey's test (α = 0.05). Pearson's correlation (95%) was used to verify the relation between the LCUs and the curing potential of RBCs. The DC at 6 mm depth was reduced when Opus BF, Opus BF Flow and Tetric N-Ceram BF were activated with Radii-cal. There was a positive correlation between the LCU irradiance and the bottom/top conversion ratios. The materials' viscosities did not affect the curing potential. Bulk-fill composites did not present higher curing potential than the conventional composite used with the incremental technique; the most important aspect of the LCU was the irradiance ratio; and the materials' viscosity did not affect the curing potential as a function of depth. Radii-cal negatively impacted the degree of conversion at 6 mm depth for most bulk-fill resin composites. Depending on the brand, bulk-fill composites may present reduced curing potential due to the light source when placed in deep cavities. Dentists should avoid LCU with acrylic tips to photoactivate bulk-fill resin-based composites.

Indexed as

Curing Lights, DentalMaterials TestingPolymerizationSurface PropertiesViscosityBulk-fillCompositeDepth of cureLight curing unitsPolymerizationViscosity

Identifiers

PMID34023954
OpenAlexW3164030590

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.