ArticleBMC gastroenterology2021
A multicenter, prospective, inpatient feasibility study to evaluate the use of an intra-colonoscopy cleansing device to optimize colon preparation in hospitalized patients: the REDUCE study.
Article in BMC gastroenterology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03503162 (Evaluation of the Bowel Cleansing in Hospitalized Patients Using Pure-Vu System), which is not on this map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Evaluation of the Bowel Cleansing in Hospitalized Patients Using Pure-Vu System
Who cites it
5 citing papers in PubMed, 10 citations in OpenAlex.
- Single-center experience with intraprocedural cleansing system to improve inadequate bowel preparation during colonoscopy.Endoscopy international open · 2024Article
- An intraprocedural cleansing system to improve inadequate bowel preparation during colonoscopy.VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy · 2024Article
- An intraprocedural bowel cleansing system for difficult-to-prepare patients-A multicenter prospective feasibility study.United European gastroenterology journal · 2024Article
- Novel use of a colonic intraprocedural cleansing device for upper gastrointestinal bleeding.Endoscopy · 2023Article
- Bowel Preparation for Pediatric Colonoscopy.Frontiers in pediatrics · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 6 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHigh quality bowel preparation prior to colonoscopy can be difficult to achieve in the inpatient setting. Hospitalized patients are at risk for extended hospital stays and low diagnostic yield due to inadequate bowel preparation. The Pure-Vu System is a novel device intended to fit over existing colonoscopes to improve intra-colonoscopy bowel preparation. The objective of the REDUCE study was to conduct the first inpatient study to evaluate optimization of bowel preparation quality following overnight preparation when using the Pure-Vu System during colonoscopy.
methodsThis multicenter, prospective feasibility study enrolled hospitalized subjects undergoing colonoscopy. Subjects recorded the clarity of their last bowel movement using a 5-point scale prior to colonoscopy. After one night of preparation, all enrolled subjects underwent colonoscopy utilizing the Pure-Vu System. The primary endpoint was improvement of colon cleanliness from baseline to post-cleansing with the Pure-Vu System as assessed by the improvement in Boston Bowel Preparation Scale (BBPS). An exploratory analysis was conducted to assess whether the clarity of the last bowel movement could predict inadequate bowel preparation.
resultsNinety-four subjects were included. BBPS analyses showed significant improvements in bowel preparation quality across all evaluable colon segments after cleansing with Pure-Vu, including left colon (1.74 vs 2.89; p < 0.0001), transverse colon (1.74 vs 2.91; p < 0.0001), and the right colon (1.41 vs 2.88; p < 0.0001). Prior to Pure-Vu, adequate cleansing (BBPS scores of ≥ 2) were reported in 60%, 62%, and 47% for the left colon, transverse colon, and right colon segments, respectively. After intra-colonoscopy cleansing with the Pure-Vu System, adequate colon preparation was reported in 100%, 99%, and 97% of the left colon, transverse colon, and right colon segments, respectively. Subjects with lower bowel movement clarity scores were more likely to have inadequate bowel preparation prior to cleansing with Pure-Vu.
conclusionsIn this feasibility study, the Pure-Vu System appears to be effective in significantly improving bowel preparation quality in hospitalized subjects undergoing colonoscopy. Clarity of last bowel movement may be useful indicator in predicting poor bowel preparation. Larger studies powered to evaluate clinical outcomes, hospital costs, and blinded BBPS assessments are required to evaluate the significance of these findings. Trial registration Evaluation of the Bowel Cleansing in Hospitalized Patients Using Pure-Vu System (NCT03503162).