Evidence map›Paper›PMID 34020039›Full record

ArticleThe Journal of molecular diagnostics : JMD2021

Real-Life Head-to-Head Comparison of Performance of Two High-Throughput Automated Assays for the Detection of SARS-CoV-2 RNA in Nasopharyngeal Swabs: The Alinity m and cobas 6800 SARS-CoV-2 Assays.

Rok Kogoj, Petra Kmetič, Anja Oštrbenk Valenčak, Kristina Fujs Komloš, Katja Seme, Martin Sagadin, Misa Korva, Mario Poljak

Open access · hybridAbstract readComparative Study
In one paragraph

Article in The Journal of molecular diagnostics : JMD, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.1field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Evaluation of the fully automated, sample-to-result Seegene STARlet-AIOS platform for detection of SARS-CoV-2, influenza virus A, influenza virus B, and RSV.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2024
    Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Rok KogojFaculty of Medicine, Institute of Microbiology and Immunology, University of Ljubljana, Ljubljana, Slovenia.
Petra KmetičFaculty of Medicine, Institute of Microbiology and Immunology, University of Ljubljana, Ljubljana, Slovenia.
Anja Oštrbenk ValenčakFaculty of Medicine, Institute of Microbiology and Immunology, University of Ljubljana, Ljubljana, Slovenia.
Kristina Fujs KomlošFaculty of Medicine, Institute of Microbiology and Immunology, University of Ljubljana, Ljubljana, Slovenia.
Katja SemeFaculty of Medicine, Institute of Microbiology and Immunology, University of Ljubljana, Ljubljana, Slovenia.
Martin SagadinFaculty of Medicine, Institute of Microbiology and Immunology, University of Ljubljana, Ljubljana, Slovenia.
Misa KorvaFaculty of Medicine, Institute of Microbiology and Immunology, University of Ljubljana, Ljubljana, Slovenia.
Mario PoljakFaculty of Medicine, Institute of Microbiology and Immunology, University of Ljubljana, Ljubljana, Slovenia. Electronic address: mario.poljak@mf.uni-lj.si.
University of Ljubljana · SI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Alinity m (Abbott Molecular, Des Plaines, IL) automated molecular analyzer allows continuous loading of samples and sample-to-result molecular detection of several microorganisms. The detection of SARS-CoV-2 by the Alinity m was compared with that of the cobas 6800 (Roche Molecular Systems, Branchburg, NJ; standard comparator) in a manufacturer-independent clinical evaluation on 2157 consecutive nasopharyngeal swab samples. Valid initial results on Alinity m and cobas 6800 were obtained from 2129 (98.7%) and 2157 (100%) samples, respectively. The overall percent agreement (95% CI) was 98.3% (2092/2129 [97.6%-98.7%]); positive percent agreement, 100% (961/961 [99.6%-100%]); negative percent agreement, 96.8% (1131/1168 [95.7%-97.7%]); and high κ value, 0.965 (0.954-0.976). There were 37 discordant results on Alinity m and, based on discordant analyses, including previous and/or follow-up PCR results, 22 could be considered analytically true positive with high probability. Due to a lack of additional information and an inability to perform repeated/further testing, the status of the remaining 15 discordant results remained unresolved. The throughput of the two analyzers was compared using testing on 564 samples in parallel across two 8-hour shifts in clinical practice. The turnaround times were compared using processing of 94 routine samples in parallel on each working day for 5 consecutive days. The two analyzers showed similar performance, with certain differences that have potential importance in some laboratory settings.

Indexed as

COVID-19COVID-19 Nucleic Acid TestingHumansNasopharynxReproducibility of ResultsRNA, ViralSARS-CoV-2RNA, Viral

Identifiers

PMID34020039
PMCPMC8131180
OpenAlexW3162952890

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.