Evidence map›Paper›PMID 34018067›Full record

ArticleEJNMMI physics2021

Innovative procedure for measuring left ventricular ejection fraction from

Emilie Verrecchia-Ramos, Olivier Morel, Paul Retif, Sinan Ben Mahmoud

Abstract read
In one paragraph

Article in EJNMMI physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Emilie Verrecchia-RamosMedical Physics Unit, CHR Metz-Thionville, Mercy Hospital, 1 allée du château, 57530 Ars-Laquenexy, Metz, France. e.verrecchiaramos@chr-metz-thionville.fr.ORCID http://orcid.org/0000-0003-4542-5021
Olivier MorelNuclear Medicine Department, CHR Metz-Thionville, Mercy Hospital, 1 allée du château, 57530 Ars-Laquenexy, Metz, France.
Paul RetifMedical Physics Unit, CHR Metz-Thionville, Mercy Hospital, 1 allée du château, 57530 Ars-Laquenexy, Metz, France.
Sinan Ben MahmoudNuclear Medicine Department, CHR Metz-Thionville, Mercy Hospital, 1 allée du château, 57530 Ars-Laquenexy, Metz, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLeft ventricular ejection fraction (LVEF) is usually measured by cine-cardiac magnetic resonance imaging (MRI), planar and single-photon emission-computerized tomography (SPECT) equilibrium radionuclide angiocardiography (ERNA), and echocardiography. It would be clinically useful to measure LVEF from first-pass positron-emission tomography/computed tomography (PET/CT) radionuclide angiography, but this approach has been limited by fast radiotracer diffusion. Ultra-sensitive digital PET systems can produce high-quality images within 3-s acquisition times. This study determined whether digital PET/CT accurately measured LVEF in an anthropomorphic heart phantom under conditions mimicking radiotracer first-pass into the cardiac cavities.

methodsHeart phantoms in end-diastole and end-systole were 3D-printed from a patient's MRI dataset. Reference left ventricle end-diastole volume (EDV), end-systole volume (ESV), and LVEF were determined by phantom weights before/after water filling. PET/CT (3-s acquisitions), MRI, and planar and SPECT ERNA were performed. EDV, ESV, and/or LVEF were measured by manual and automated cardiac cavity delineation, using clinical segmentation softwares. LVEF was also measured from PET images converted to 2D "pseudo-planar" images along the short axis and horizontal long axis. LVEF was also calculated for planar ERNA images. All LVEF, ESV and EDV values were compared to the reference values assessed by weighing.

resultsManually calculated 3D-PET-CT-based EDV, ESV, and LVEF were close to MRI and reference values. Automated calculations on the 3D-PET-CT dataset were unreliable, suggesting that the SPECT-based tool used for this calculation is not well adapted for PET acquisitions. Manual and automated LVEF estimations from "pseudo-planar" PET images were very close/identical to MRI and reference values.

conclusionsFirst-pass "pseudo-planar" PET may be a promising method for estimating LVEF, easy to use in clinical practice. Processing 3D PET images is also a valid method but to date suffers from a lack of well-suited software for automated LV segmentation.

Indexed as

Digital PET/CTFirst-passHeart phantomLVEF“Pseudo-planar” PET

Identifiers

PMID34018067
PMCPMC8137784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.