Evidence map›Paper›PMID 34014978›Full record

ArticlePloS one2021

UV light-emitting diode (UV-LED) at 265 nm as a potential light source for disinfecting human platelet concentrates.

Tomoya Hayashi, Kumiko Oguma, Yoshihiro Fujimura, Rika A Furuta, Mitsunobu Tanaka, Mikako Masaki, Yasuhito Shinbata, Takafumi Kimura, Yoshihiko Tani, Fumiya Hirayama and 2 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.6field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Irradiation with 265-nm Ultraviolet Light-Emitting Diodes to Plasma: Alterations of Hemostatic Parameters and von Willebrand Factor.Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie · 2025
    Article
  3. Article
  4. Review
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 1 country.

Tomoya HayashiJapanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan.ORCID 0000-0002-1776-0052
Kumiko OgumaThe University of Tokyo, Tokyo, Japan.
Yoshihiro FujimuraJapanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan.
Rika A FurutaCentral Blood Institute, Japanese Red Cross, Tokyo, Japan.
Mitsunobu TanakaJapanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan.
Mikako MasakiJapanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan.
Yasuhito ShinbataJapanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan.
Takafumi KimuraJapanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan.
Yoshihiko TaniCentral Blood Institute, Japanese Red Cross, Tokyo, Japan.
Fumiya HirayamaJapanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan.
Yoshihiro TakiharaJapanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan.
Koki TakahashiBlood Service Headquarters, Japanese Red Cross, Tokyo, Japan.
Japanese Red Cross Society, Japan · JPThe University of Tokyo · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The risk of sepsis through bacterial transmission is one of the most serious problems in platelet transfusion. In processing platelet concentrates (PCs), several methods have been put into practice to minimize the risk of bacterial transmission, such as stringent monitoring by cultivation assays and inactivation treatment by photoirradiation with or without chemical agents. As another potential option, we applied a light-emitting diode (LED) with a peak emission wavelength of 265 nm, which has been shown to be effective for water, to disinfect PCs. In a bench-scale UV-LED exposure setup, a 10-min irradiation, corresponding to an average fluence of 9.2 mJ/cm2, resulted in >2.0 log, 1.0 log, and 0.6 log inactivation (mean, n = 6) of Escherichia coli, Staphylococcus aureus, and Bacillus cereus, respectively, in non-diluted plasma PCs. After a 30-min exposure, platelet counts decreased slightly (18 ± 7%: mean ± SD, n = 7); however, platelet surface expressions of CD42b, CD61, CD62P, and PAC-1 binding did not change significantly (P>0.005), and agonist-induced aggregation and adhesion/aggregation under flow conditions were well maintained. Our findings indicated that the 265 nm UV-LED has high potential as a novel disinfection method to ensure the microbial safety of platelet transfusion.

Indexed as

Blood PlateletsDisinfectionUltraviolet RaysBacteriaHumansMicrobial Viability

Identifiers

PMID34014978
PMCPMC8136854
OpenAlexW3162691310

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.