Evidence map›Paper›PMID 34014460›Full record

ArticleInternational ophthalmology2021

The novel haptic-twist method for a sutureless double-needle intrascleral haptic fixation technique.

Tansu Erakgun, Hamidu Hamisi Gobeka

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in International ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07446829 (Effect of Different Needle Insertion Positions on the Clinical Outcomes of YAMANE Technique for Intrascleral Intraocular Lens Fixation), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07446829 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Effect of Different Needle Insertion Positions on the Clinical Outcomes of YAMANE Technique for Intrascleral Intraocular Lens Fixation: a Randomized Controlled Trial

TypeinterventionalSponsorZhongshan Ophthalmic Center, Sun Yat-sen UniversityRan2026 to 2027Enrolled54ConditionsCongenital Ectopia LentisArmsYAMANE technique(Suture Needle Insertion at 2.5 mm Posterior to the Limbus)
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Tansu ErakgunKaskaloglu Eye Hospital, Izmir, Turkey.ORCID http://orcid.org/0000-0003-2912-6179
Hamidu Hamisi GobekaDepartment of Ophthalmology, Faculty of Medicine, Agri Ibrahim Cecen University Rectorate, Erzurum Yolu 4 Km, 04100, Merkez, Agri, Turkey. hgobeka@gmail.com.ORCID http://orcid.org/0000-0002-7656-3155

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDescription of a novel modified technique known as haptic-twist method for placing a trailing haptic into a 27 G needle during double-needle intrascleral haptic fixation (Yamane technique) in the absence and/or inadequacy of capsular support.

methodsThe trailing haptic was threaded into the needle lumen using a haptic-twist method in 12 eyes of 11 patients with aphakia. The haptic was grasped by a forceps 2-3 mm from the tip, while the forceps was rotated by 180° counter-clockwise around its own axis. This maneuver enabled the trailing haptic to be slightly twisted without any deformation and to coordinate with the needle in the proper angle. The surgical technique has also been mentioned in a surgical video.

resultsMean age of the patients was 62 years ± 18 (range 46-78 years). Although the mean pre-operative best-corrected visual acuity was 0.70 ± 0.35 logarithm of the minimum angle of resolution (logMAR) (range 1.30-0.20 logMAR), an improvement of up to 0.40 ± 0.32 logMAR (range 1.0-0.1 logMAR) was observed 3 months after surgery. No trailing haptic bending or breakage was observed during the process. Furthermore, no optical tilting or decentralization was observed post-operatively.

conclusionsAlthough threading the leading haptic into the needle is reasonably straightforward, the trailing haptic positioning can be difficult due to an inappropriate gesture of both the haptic and the needle. We fervently believe that this novel haptic-twist method can provide a much simpler and easier approach, and thus contribute to better surgical outcomes.

Indexed as

Lenses, IntraocularAgedHumansLens Implantation, IntraocularMiddle AgedScleraSuture TechniquesVisual AcuityAphakiaHaptic-twist methodIntrascleral haptic fixationSecondary IOL implantationTrailing haptic

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials