Trial reportIndian journal of ophthalmology2021
The effect of corneal crosslinking on the rigidity of the cornea estimated using a modified algorithm for the Schiøtz tonometer.
Trial report in Indian journal of ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Evaluation of the Relationship Between the Changes in the Corneal Biomechanical Properties and Changes in the Anterior Segment OCT Parameters Following Customized Corneal Cross-Linking.Clinical ophthalmology (Auckland, N.Z.) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The aim of this study was to test a method for estimating corneal rigidity before and after cross-linking (CXL) using a Schiøtz tonometer. Methods: The study was performed in the Kyiv City Clinical Ophthalmological Hospital "Eye Microsurgical Center", Ukraine. This was a prospective, consecutive, randomized, masked, case-by-case, clinical study. Corneal rigidity, indicated by the gradient (G) between lg applied weight and corresponding lg scale reading during Schiøtz tonometry, were obtained by increasing (A-mode) then reducing (D-mode) weights by two operators [A] in keratoconus, post-CXL and control subjects for estimation of (i) interoperator and (ii) intersessional errors, (iii) intergroup differences; [B] before and after CXL. Central corneal thickness CCT was measured by scanning slit pachymetry. ANOVA, t tests, linear regression were the statistical tools used. Results: Average interoperator difference (ΔG) was -0.120 (SD = ±0.294, 95%CI = -0.175 to -0.066). A significant correlation between ΔG and the mean of each pair of G values was found (r = -0.196, n = 112, P = 0.038). Intersessional differences in mean G values were insignificant (P > 0.05). There was a significant correlation between G at first session (X Conclusion: Corneal rigidity (G) estimated using the Schiøtz tonometer can be useful for detecting changes after CXL. However, G values are linked to CCT, can vary from time-to-time and the procedure is operator dependent.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials