ArticlePediatric radiology2021
Utilization of 3-T fetal magnetic resonance imaging in clinical practice: a single-institution experience.
Article in Pediatric radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 12 citations in OpenAlex.
- Improving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI.Journal of magnetic resonance imaging : JMRI · 2025Article
- Effect of magnet strength on fetal brain biometry - a single-center retrospective MRI-based cohort study.Neuroradiology · 2023Article
- Fetal brain MRI: neurometrics, typical diagnoses, and resolving common dilemmas.The British journal of radiology · 2023Review
- Fetal cardiovascular blood flow MRI: techniques and applications.The British journal of radiology · 2023Review
- ISUOG Practice Guidelines (updated): performance of fetal magnetic resonance imaging.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2023Article
- Magnetic resonance imaging of the monkey fetal brain in utero.Investigative magnetic resonance imaging · 2022Article
- Clinical Applications of Fetal MRI in the Brain.Diagnostics (Basel, Switzerland) · 2022Review
- Maternal blood inflammatory marker levels increased in fetuses with ventriculomegaly.Frontiers in human neuroscience · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAs the safety and efficacy of fetal magnetic resonance imaging (MRI) at 3 tesla (T) continues to evolve, understanding its potential benefits and limitations is becoming increasingly important.
objectiveWe aim to compare the image quality of fetal MRI between 1.5 T and 3 T in routine clinical practice. MATERIALS AND
methodsFetal MRIs performed at 3 T between Jan. 1, 2019, and Dec. 31, 2019, at our institution were retrospectively reviewed by four fellowship-trained subspecialty radiologists. Imaging quality by system, sequence and artifacts were compared with matched controls at 1.5 T and rated using a modified Likert scale.
resultsThirty-three fetal MRIs at 3 T were reviewed, and a control group of studies for the same clinical indication and equivalent gestational age were selected for comparison. Two of the four radiologists preferred 3-T image quality of the brain with slight agreement among the four reviewers (k=0.19, P=0.01). Three of the four radiologists had no preference for 1.5 T vs. 3 T in the majority of cases in evaluating the chest and abdomen. In the overall assessment, 3 T was preferred in less than half of cases by all four radiologists (k=0.07, P=0.26). In the evaluation of standing wave, moire fringe and magnetic susceptibility artifacts, 3 T was not preferred in the majority of studies by all four radiologists. Total exam time was significantly longer in the 3-T fetal MRIs (75.0±15.1 min) compared to the 1.5-T fetal MRIs (55.5±13.3 min, P<0.001).
conclusionWhile 3 T is a feasible alternative to 1.5 T for fetal MRI, the increased artifacts and longer exam times observed at 3 T without clear improvement in overall image quality make 1.5 T preferable for fetal MRI in routine clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.