Evidence map›Paper›PMID 34008854›Full record

ArticleJournal of biomechanical engineering2021

Effect of Dielectric Material and Package Stiffness on the Power Generation in a Packaged Triboelectric Energy Harvesting System for Total Knee Replacement.

Nabid Aunjum Hossain, Geofrey George Yamomo, Ryan Willing, Shahrzad Towfighian

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanical engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Nabid Aunjum HossainDepartment of Mechanical Engineering, Binghamton University, 4400 Vestal Parkway E., Binghamton, NY 13902.
Geofrey George YamomoDepartment of Mechanical and Materials Engineering, University of Western Ontario, 1151 Richmond Street N., London, ON N6A 5B9, Canada.
Ryan WillingDepartment of Mechanical and Materials Engineering, University of Western Ontario, 1151 Richmond Street N., London, ON N6A 5B9, Canada.
Shahrzad TowfighianDepartment of Mechanical Engineering, Binghamton University, 4400 Vestal Parkway E., Binghamton, NY 13902.
Binghamton University · USWestern University · CA

Funding

An implantable self-powered load sensor for total knee replacement health monitoringR21AR068572 · NIAMS · STATE UNIVERSITY OF NY,BINGHAMTON · PI SALMAN, EMRE, TOWFIGHIAN, SHAHRZAD · 2017 to 2018
$349k
NIAMS NIH HHS R21 AR068572
6 · The paper itself

Abstract

The objectives of this study are to experimentally investigate the effects of the dielectric material and the package stiffness on the durability and the efficiency of a previously developed triboelectric-based instrumented knee implant prototype. The proposed smart knee implant may provide useful information about prosthesis health and its functionality after a total knee replacement (TKR) by routine monitoring of tibiofemoral load transfer without the need for any external power source. The triboelectric powered load sensing by the proposed TKR system needs to be functional throughout the entire life of a knee replacement. The power output of the triboelectric system depends on the surface charge generations and accumulations on its dielectric material, and the force that transmits through its housing into the tribo-materials. The properties of the dielectric material and the package stiffness can significantly influence the reliability of the proposed device. For such a TKR system, a compliant mechanism with the ideal material selection can improve its state of the art. We investigated the performance of three vertical contact mode triboelectric generators made with three different dielectric materials: polydimethylsiloxane (PDMS), fluorinated ethylene propylene (FEP), and polytetrafluoroethylene (PTFE). To investigate the effect of package stiffness, we tested two Ti-PDMS-Ti harvesters inside a polyethylene and a Ti6Al4V package. At 1500 N of sinusoidal loads, the harvesters could generate 67.73 μW and 19.81 μW of mean apparent power in parallel and single connections in the polyethylene package, which was 32 and 17 times greater than the power recorded in the Ti assembly, respectively.

Indexed as

Arthroplasty, Replacement, KneeElectric Power SuppliesKnee ProsthesisMaterials TestingMechanical PhenomenaProsthesis DesignTitaniumTitaniumbiomedical sensordielectric effect in triboelectric generatorsenergy harvestinginstrumented knee implantpackage stiffness

Identifiers

PMID34008854
PMCPMC8299800
OpenAlexW3160757062

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.