Evidence map›Paper›PMID 34007224›Full record

ArticleMedical devices (Auckland, N.Z.)2021

Thermographic Assessment of Reperfusion Profile Following Using a Tourniquet in Total Knee Arthroplasty: A Prospective Observational Study.

Mohammed Alisi, Jihad Al-Ajlouni, Mohammed Kareem Ibsais, Zeinab Obeid, Yazan Hammad, Ahmad Alelaumi, Munther Al-Saber, Odai Abuasbeh, Feras Abuhajleh

Open access · goldAbstract read
In one paragraph

Article in Medical devices (Auckland, N.Z.), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Mohammed AlisiDepartment of Special Surgery, Division of Orthopaedics, School of Medicine, The University of Jordan, Amman, Jordan.ORCID 0000-0003-3694-2801
Jihad Al-AjlouniDepartment of Special Surgery, Division of Orthopaedics, School of Medicine, The University of Jordan, Amman, Jordan.ORCID 0000-0002-1980-977X
Mohammed Kareem IbsaisSchool of Medicine, The University of Jordan, Amman, Jordan.
Zeinab ObeidSchool of Medicine, The University of Jordan, Amman, Jordan.
Yazan HammadDepartment of Special Surgery, Division of Orthopaedics, School of Medicine, The University of Jordan, Amman, Jordan.ORCID 0000-0002-0394-5654
Ahmad AlelaumiDepartment of Special Surgery, Division of Orthopaedics, School of Medicine, The University of Jordan, Amman, Jordan.
Munther Al-SaberDepartment of Special Surgery, Division of Orthopaedics, School of Medicine, The University of Jordan, Amman, Jordan.
Odai AbuasbehDepartment of Special Surgery, Division of Orthopaedics, School of Medicine, The University of Jordan, Amman, Jordan.
Feras AbuhajlehDepartment of Special Surgery, Division of Orthopaedics, School of Medicine, The University of Jordan, Amman, Jordan.
University of Jordan · JO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInfrared thermal imaging is a non-invasive technique capable of detecting changes in temperature that could ultimately signify changes in blood supply. Flir One is a smartphone-based thermal camera, working by a downloadable application, capable of detecting the limb temperature through a non-contact method using infrared thermography technology. Using the Flir One camera, we will assess the lower limb reperfusion profile following the tourniquet release post total knee arthroplasty (TKA).

methodsA prospective study included 46 patients who underwent primary TKA. We used the (Flir One Gen 3) thermographic camera to capture images at ankle joint preoperatively, and at 1, 10, and 20 minutes post tourniquet release on operation side. The contralateral ankle stands as control.

resultsThe mean preoperative temperature (in Celsius) of ankle control side and operated side were 33.03 (SD=1.65) and 33.26 (SD=1.42), respectively. The mean ankle temperature on operation side was 19.73 (SD=2.85), 30.49 (SD=2), and 32.43 (SD=1.31) at 1, 10, and 20 minutes post tourniquet release, respectively, while the control side showed a mean temperature of 32.85 (SD=1.42), 32.84 (SD=0.91), and 33.15 (SD=0.95) at the same time intervals. There was a significant statistical difference between both ankle temperatures at 1 and 10 minutes (P=0.00 for each time). At 20 minutes, 37 ankles (80.4%) at operation side reached a temperature level similar but below the level of control side; however, the difference was not significant (P=0.692).

conclusionInfrared thermography using the smartphone-connected camera is a simple, non-invasive, feasible, and reliable technology. It provides an objective measure to assess the perfusion status of the limbs. In TKA, the distal limb will reach full reperfusion status after approximately 20 minutes of tourniquet release.

Indexed as

infraredperfusiontemperaturethermal imagingthermographytotal knee arthroplasty

Identifiers

PMID34007224
PMCPMC8122004
OpenAlexW3160478577

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.