Article in Translational vision science & technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Deep learning and optical coherence tomography in glaucoma: Bridging the diagnostic gap on structural imaging.Frontiers in ophthalmology · 2022Pooled it
- Bridging the resources gap: deep learning for fluorescein angiography and optical coherence tomography macular thickness map image translation.BMC ophthalmology · 2022Trial
- Generative artificial intelligence in ophthalmology: a scoping review of current applications, opportunities, and challenges.Eye (London, England) · 2025Article
- Artificial Intelligence for Optical Coherence Tomography in Glaucoma.Translational vision science & technology · 2025Review
- Synthetic data in medical imaging within the EHDS: a path forward for ethics, regulation, and standards.Frontiers in digital health · 2025Review
- Generating Synthesized Fluorescein Angiography Images From Color Fundus Images by Generative Adversarial Networks for Macular Edema Assessment.Translational vision science & technology · 2024Article
- Unsupervised synthesis of realistic coronary artery X-ray angiogram.International journal of computer assisted radiology and surgery · 2023Article
- Generative Adversarial Networks in Medicine: Important Considerations for this Emerging Innovation in Artificial Intelligence.Annals of biomedical engineering · 2023Review
- Machine learning-couched treatment algorithms tailored to individualized profile of patients with primary anterior chamber angle closure predisposed to the glaucomatous optic neuropathy.The EPMA journal · 2023Article
- Generating Synthesized Ultrasound Biomicroscopy Images from Anterior Segment Optical Coherent Tomography Images by Generative Adversarial Networks for Iridociliary Assessment.Ophthalmology and therapy · 2022Article
- Evaluation of Generative Adversarial Networks for High-Resolution Synthetic Image Generation of Circumpapillary Optical Coherence Tomography Images for Glaucoma.JAMA ophthalmology · 2022Article
- Application of generative adversarial networks (GAN) for ophthalmology image domains: a survey.Eye and vision (London, England) · 2022Review
- A review of generative adversarial network applications in optical coherence tomography image analysis.Journal of optometry · 2022Review
- Prediction of corneal astigmatism based on corneal tomography after femtosecond laser arcuate keratotomy using a pix2pix conditional generative adversarial network.Frontiers in public health · 2022Article
- Deepfakes in Ophthalmology: Applications and Realism of Synthetic Retinal Images from Generative Adversarial Networks.Ophthalmology science · 2021Article
- Applications of deep learning in the analysis of optical coherence tomography images for glaucoma-related diagnostics.Taiwan journal of ophthalmologyReview
- A GAN-based deep enhancer for quality enhancement of retinal images photographed by a handheld fundus camera.Advances in ophthalmology practice and researchArticle
- Big data for imaging assessment in glaucoma.Taiwan journal of ophthalmologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To develop generative adversarial networks (GANs) that synthesize realistic anterior segment optical coherence tomography (AS-OCT) images and evaluate deep learning (DL) models that are trained on real and synthetic datasets for detecting angle closure. Methods: The GAN architecture was adopted and trained on the dataset with AS-OCT images collected from the Joint Shantou International Eye Center of Shantou University and the Chinese University of Hong Kong, synthesizing open- and closed-angle AS-OCT images. A visual Turing test with two glaucoma specialists was performed to assess the image quality of real and synthetic images. DL models, trained on either real or synthetic datasets, were developed. Using the clinicians' grading of the AS-OCT images as the reference standard, we compared the diagnostic performance of open-angle vs. closed-angle detection of DL models and the AS-OCT parameter, defined as a trabecular-iris space area 750 µm anterior to the scleral spur (TISA750), in a small independent validation dataset. Results: The GAN training included 28,643 AS-OCT anterior chamber angle (ACA) images. The real and synthetic datasets for DL model training have an equal distribution of open- and closed-angle images (all with 10,000 images each). The independent validation dataset included 238 open-angle and 243 closed-angle AS-OCT ACA images. The image quality of real versus synthetic AS-OCT images was similar, as assessed by the two glaucoma specialists, except for the scleral spur visibility. For the independent validation dataset, both DL models achieved higher areas under the curve compared with TISA750. Two DL models had areas under the curve of 0.97 (95% confidence interval, 0.96-0.99) and 0.94 (95% confidence interval, 0.92-0.96). Conclusions: The GAN synthetic AS-OCT images appeared to be of good quality, according to the glaucoma specialists. The DL models, trained on all-synthetic AS-OCT images, can achieve high diagnostic performance. Translational Relevance: The GANs can generate realistic AS-OCT images, which can also be used to train DL models.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials