Evidence map›Paper›PMID 34004011›Full record

ArticleTranslational vision science & technology2021

The Influence of Cataract on Fluorescence Lifetime Imaging Ophthalmoscopy (FLIO).

Joel-Benjamin Lincke, Chantal Dysli, Damian Jaggi, Rahel Fink, Sebastian Wolf, Martin S Zinkernagel

Abstract read
In one paragraph

Article in Translational vision science & technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Joel-Benjamin LinckeDepartment of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland.
Chantal DysliDepartment of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland.
Damian JaggiDepartment of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland.
Rahel FinkDepartment of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland.
Sebastian WolfDepartment of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland.
Martin S ZinkernagelDepartment of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To investigate the influence of lens opacifications on fluorescence lifetime imaging ophthalmoscopy (FLIO). Methods: Forty-seven eyes of 45 patients were included. Mean fluorescence lifetimes (Tm) were recorded with a fluorescence lifetime imaging ophthalmoscope in a short spectral channel (SSC) and a long spectral channel (LSC). Retinal and lens autofluorescence lifetimes were measured in subjects before and after cataract surgery. Lens opacification was graded using the Lens Opacities Classification System III (LOCS III) classification. Results: The retinal Tm decreased significantly after cataract surgery in both spectral channels (SSC: -53%, P < 0.0001; LSC: -26%, P = 0.0041). The lens Tm differed significantly between the crystalline and the artificial lens in both spectral channels (P < 0.0001). The "nuclear opacity" and "nuclear color" score of the LOCS III classification correlated significantly with the mean Tm difference in both spectral channels (P < 0.0001). Conclusions: Lens opacification results in significantly longer retinal Tm. Therefore the lens status has to be considered when performing cross-sectional fluorescence lifetime analysis. Cataract-formation and cataract-surgery needs to be considered when conducting longitudinal studies. Grading of nuclear opacity following the LOCS III classification provides an approximate conversion formula for the mean change of lifetimes, which can be helpful in the interpretation of data in patients with lens opacities. Translational Relevance: FLIO is significantly influenced by lens opacities. Using a lens opacity grading scheme and measuring fluorescence lifetimes before and after cataract surgery, an approximative conversion formula can be calculated, which enables the comparison of lifetimes after cataract surgery or over the course of time.

Indexed as

CataractRetinaCross-Sectional StudiesHumansOphthalmoscopyOptical Imaging

Identifiers

PMID34004011
PMCPMC8088233

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.