Evidence map›Paper›PMID 34003818›Full record

ArticlePloS one2021

Reliability of pelvic floor muscle surface electromyography (sEMG) recordings during synchronous whole body vibration.

Daria Chmielewska, Grzegorz Sobota, Paweł Dolibog, Patrycja Dolibog, Agnieszka Opala-Berdzik

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Daria ChmielewskaElectromyography and Pelvic Floor Muscles Laboratory, Department of Physical Medicine, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland.ORCID 0000-0001-9569-1980
Grzegorz SobotaDepartment of Human Motor Behavior, Institute of Sport Science, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland.ORCID 0000-0002-8281-0431
Paweł DolibogDepartment and Faculty of Medical Biophysics, Medical University of Silesia, Katowice, Poland.
Patrycja DolibogDepartment and Faculty of Medical Biophysics, Medical University of Silesia, Katowice, Poland.
Agnieszka Opala-BerdzikDepartment of Physiotherapy in Internal Diseases, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland.
Akademii Wychowania Fizycznego im. Jerzego Kukuczki w Katowicach · PLMedical University of Silesia · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The primary aim of the study was to assess intraday and interday reliability of surface electromyography (sEMG) reflex activity of the pelvic floor muscles during synchronous whole-body vibration (S-WBV) of two intensities (30Hz/2mm; 40Hz/4mm) using band-stop filter and high-pass filter signal processing. The secondary aim of the study was to assess intraday and interday (test-retest) reliability of sEMG obtained from maximal voluntary contraction (MVC) test. We evaluated the intraday reliability of sEMG recordings obtained during sessions 1 and 2 performed on the same day. The sessions consisting of maximal voluntary pelvic floor muscle contraction and synchronous vibration sets with 1-hour rest in-between sessions 1 and 2 in healthy nulliparous women. The next intraday reliability was evaluated between the results of sessions 3 and 4 performed on the same day but followed at an interval of 4 weeks. to include the entire menstrual cycle. The interday reliability was determined based on the results of sessions 1 and 3 using the intraclass correlation coefficient (ICC 3,3). The intraday ICCs for band-stop filtered mean and median sEMG frequency and mean normalized sEMGRMS amplitude of the 30Hz/2mm (ICC = 0.89-0.99) and 40Hz/4mm vibration (ICC = 0.95-0.99) indicated substantial reproducibility. The intraday reliability of high-pass filter at 100-450Hz for these parameters was also substantial (30Hz/2mm ICC of 0.92 to 0.98; 40Hz/4mm ICC of 0.88 to 0.98). The interday reliability (session 1 vs. session 3) of the mean normalized sEMGRMS amplitude for band-stop filtered means of 40 Hz/4mm and 30Hz/2mm vibration recordings was substantial (ICC = 0.82 and 0.93). However, ICCs of the mean and median frequency were indicative of fair reliability (ICC of 0.43 to 0.59). The interday reliability of mean normalized sEMGRMS amplitude for high-pass filter at 100-450Hz was substantial (30Hz/2mm ICC of 0.90; 40Hz/4mm ICC of 0.73) for the 30Hz/2mm S-WBV and moderate (ICC = 0.73) for the 40/4mm S-WBV. The ICCs for mean and median sEMG frequency ICCs indicated slight to fair reproducibility (ICC of 0.16 to 0.56). The intraday reliability of the strongest MVC contraction and average MVC turned out substantial (ICC = 0.91-0.98). The interday reliability coefficients of the strongest MVC contraction and average MVCs were 0.91 and 0.82, respectively. Concluded, the intraday reliability proved satisfactory for all variables; however, the interday comparison showed sufficient ICC levels only for the mean amplitude. We therefore recommend this parameter should be used when analyzing PFM sEMG recorded during vibration. ICCs of the mean and median frequency for both signal processing methods were indicative of insufficient reliability and did not reach the threshold for usefulness. Our study showed similar reliability of PFM sEMG during S-WBV in case of the two filtering methods used.

Indexed as

AdultElectromyographyFemaleHumansIsometric ContractionLower ExtremityMuscle ContractionMuscle, SkeletalPelvic FloorReproducibility of ResultsVibrationYoung Adult

Identifiers

PMID34003818
PMCPMC8130969
OpenAlexW3161730674

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.