Evidence map›Paper›PMID 34001274›Full record

ArticleJournal of orthopaedic surgery and research2021

Medium term outcome of Lancaster cortical window technique for extraction of femoral stem in revision hip arthroplasty.

Amit Singh, Sunirmal Mukherjee, Kuntal Patel, Deepak Herlekar, Srikant Gandavaram, Nicholas Charalambous

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Amit SinghUniversity Hospital of Morecambe Bay NHS Foundation Trust, Ashton Road, Lancaster, LA1 4RP, UK. Amit.singh@mbht.nhs.uk.ORCID http://orcid.org/0000-0002-6437-9975
Sunirmal MukherjeeUniversity Hospital of Morecambe Bay NHS Foundation Trust, Ashton Road, Lancaster, LA1 4RP, UK.
Kuntal PatelUniversity Hospital of Morecambe Bay NHS Foundation Trust, Ashton Road, Lancaster, LA1 4RP, UK.
Deepak HerlekarUniversity Hospital of Morecambe Bay NHS Foundation Trust, Ashton Road, Lancaster, LA1 4RP, UK.
Srikant GandavaramUniversity Hospital of Morecambe Bay NHS Foundation Trust, Ashton Road, Lancaster, LA1 4RP, UK.
Nicholas CharalambousUniversity Hospital of Morecambe Bay NHS Foundation Trust, Ashton Road, Lancaster, LA1 4RP, UK.
University Hospitals of Morecambe Bay NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe extraction of a femoral stem during the revision hip arthroplasty can be a daunting task and can lead to catastrophic complications for the patient. A sound technique employed intraoperatively helps in the speedy recovery of the patient and reduces the risk of future surgical interventions. In this study, we present a medium-term outcome of our novel Lancaster cortical window technique which can be used for the removal of cemented or uncemented femoral stems.

methodsThe study was conducted at a specialist centre in the north-west of the UK from January 2014 to May 2019. This is a retrospective case series where patients were treated surgically using the Lancaster cortical window technique for removal of the femoral implant during a revision hip arthroplasty. Patient's electronic notes and radiographs were used to evaluate the functional and radiological outcome.

resultsIn this study, 18 patients were managed surgically using the novel Lancaster window technique. The mean age of all the patients was 81.5 years, and the male to female ratio was 10:8. Fifteen patients underwent revision surgery for aseptic loosening of the femoral and acetabular components. The rest of the three patients had revision surgery for a broken femoral stem, intraoperative femoral canal perforation while implanting a total hip replacement femoral stem and infection. Twelve femurs were replanted with uncemented long femoral stems and six with long cemented stems. The cortical window osteotomy united in all the patients in 4.2 months (mean). The mean follow-up of these patients is 20.9 months, and none of them had any implant subsidence or loosening at the time of their last follow-up.

conclusionWe believe Lancaster cortical window technique can be safely used for the removal of cemented stems during revision hip arthroplasty without the need for expensive equipment.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisProsthesis DesignProsthesis FailureAgedAged, 80 and overBone CementsFemaleHumansMalePain MeasurementReoperationRetrospective StudiesBone CementsExtraction of the femoral stemOsteotomyRevision hip arthroplasty

Identifiers

PMID34001274
PMCPMC8127230
OpenAlexW3124521531

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.