ArticlePloS one2021
Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study.
Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 19 citations in OpenAlex.
- A hybrid phenomenological finite element model of transcatheter aortic valve leaflet behaviour under non-circular annular deployment: in vitro validation and biomechanical insights.Biomechanics and modeling in mechanobiology · 2026Article
- Mechanical Behavior of Valve Stents in Diverse Bicuspid Aortic Valves: Influence of Structural Design and Annular Eccentricity.Cardiovascular engineering and technology · 2026Article
- The impact of bicuspid valve morphology on the selection of transcatheter aortic valve implantation devices: anEuropean heart journal. Imaging methods and practice · 2025Article
- Raphe-Type Bicuspid Aortic Valve as a Risk Factor for Transcatheter Aortic Valve Replacement Failure: Improving Outcomes Using the LIRA Method and the Medtronic FX Prosthesis.Journal of cardiovascular development and disease · 2024Article
- Probing the limits and capabilities of diffusion models for the anatomic editing of digital twins.NPJ digital medicine · 2024Article
- Computational Model for Early-Stage Aortic Valve Calcification Shows Hemodynamic Biomarkers.Bioengineering (Basel, Switzerland) · 2024Article
- The Natural History of Bicuspid Aortic Valve Disease.Structural heart : the journal of the Heart Team · 2023Review
- Leaflet Stresses During Full Device Simulation of Crimping to 6 mm in Transcatheter Aortic Valve Implantation, TAVI.Cardiovascular engineering and technology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 2 countries.
Funding
Abstract
The bicuspid aortic valve (BAV) is a common and heterogeneous congenital heart abnormality that is often complicated by aortic stenosis. Although initially developed for tricuspid aortic valves (TAV), transcatheter aortic valve replacement (TAVR) devices are increasingly applied to the treatment of BAV stenosis. It is known that patient-device relationship between TAVR and BAV are not equivalent to those observed in TAV but the nature of these differences are not well understood. We sought to better understand the patient-device relationships between TAVR devices and the two most common morphologies of BAV. We performed finite element simulation of TAVR deployment into three cases of idealized aortic anatomies (TAV, Sievers 0 BAV, Sievers 1 BAV), derived from patient-specific measurements. Valve leaflet von Mises stress at the aortic commissures differed by valve configuration over a ten-fold range (TAV: 0.55 MPa, Sievers 0: 6.64 MPa, and Sievers 1: 4.19 MPa). First principle stress on the aortic wall was greater in Sievers 1 (0.316 MPa) and Sievers 0 BAV (0.137 MPa) compared to TAV (0.056 MPa). TAVR placement in Sievers 1 BAV demonstrated significant device asymmetric alignment, with 1.09 mm of displacement between the center of the device measured at the annulus and at the leaflet free edge. This orifice displacement was marginal in TAV (0.33 mm) and even lower in Sievers 0 BAV (0.23 mm). BAV TAVR, depending on the subtype involved, may encounter disparate combinations of device under expansion and asymmetry compared to TAV deployment. Understanding the impacts of BAV morphology on patient-device relationships can help improve device selection, patient eligibility, and the overall safety of TAVR in BAV.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials