Evidence map›Paper›PMID 33999265›Full record

ArticleHerzschrittmachertherapie & Elektrophysiologie2021

Newer generation cryoballoon vs. contact force-sensing radiofrequency ablation catheter in the ablation of paroxysmal atrial fibrillation.

Ahmed Nabil Ali, Omar Riad, Mazen Tawfik, Aaisha Opel, Tom Wong

Abstract read
PubMed Publisher
In one paragraph

Article in Herzschrittmachertherapie & Elektrophysiologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Ahmed Nabil AliCardiology Department, Faculty of Medicine, Ain Shams University, Ramsis street, Abbaseya, 11517, Cairo, Egypt. ahmednabil_80@yahoo.com.ORCID http://orcid.org/0000-0003-4323-6243
Omar RiadCardiology Department, Faculty of Medicine, Ain Shams University, Ramsis street, Abbaseya, 11517, Cairo, Egypt.
Mazen TawfikCardiology Department, Faculty of Medicine, Ain Shams University, Ramsis street, Abbaseya, 11517, Cairo, Egypt.
Aaisha OpelCardiology Department, Royal Brompton and Harefield NHS trust, London, UK.
Tom WongCardiology Department, Royal Brompton and Harefield NHS trust, London, UK.
Ain Shams University · EGRoyal Brompton & Harefield NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCatheter ablation for atrial fibrillation (AF) has become an effective treatment to control symptoms. The second generation cryoballoon (CB) was designed for more efficient and homogenous freeze. Radiofrequency (RF) ablation catheters using three-dimensional electroanatomical mapping with the use of contact-force radiofrequency (CF RF) technology has achieved good results in several studies.

objectivesTo compare the efficacy and safety of second-generation CB ablation in contrast to CF RF ablation in the ablation of paroxysmal AF.

methodsA total of 81 consecutive patients suffering from paroxysmal AF underwent pulmonary vein isolation (PVI) either by the second generation cryoballoon (n = 44) or a contact force-sensing RF catheter (n = 37). The study was conducted at Ain Shams University Hospitals and Royal Brompton & Harefield NHS trust. Baseline data, procedural data and patient follow up-at 3, 6 and 12 months-were collected and analysed.

resultsThe mean age was 53.8 ± 15 years in the CB group and 62.4 ± 12 years in the RF group, females representing 40.9% and 48.6% respectively. The baseline characteristics were comparable, but the CB group had less left atrial diameter and more left ventricular ejection fraction. The CB procedure was shorter (94.4 ± 39.3 vs. 140.8 ± 44.3 min, p < 0.0001), with longer fluoroscopy time (30 vs. 15.1 min, p = 0.047). Procedural complications were comparable between the two groups (CB 4.6%, CF RF 2.7%, p = 0.411). After 1 year, the recurrence rate in the CB group was similar to RF (27.3% vs. 27% respectively, p = 0.980).

conclusionSecond-generation CB ablation of paroxysmal AF has similar efficacy and safety to contact force-sensing RF catheters, with shorter procedure times and more fluoroscopy.

Indexed as

Atrial FibrillationCatheter AblationCryosurgeryPulmonary VeinsAdultAgedCathetersFemaleHumansMiddle AgedRecurrenceStroke VolumeTime FactorsTreatment OutcomeVentricular Function, LeftAtrial fibrillationCatheter ablationCryoballoon ablationPulmonary vein isolation

Identifiers

PMID33999265
OpenAlexW3163061161

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.