ArticleHerzschrittmachertherapie & Elektrophysiologie2021
Newer generation cryoballoon vs. contact force-sensing radiofrequency ablation catheter in the ablation of paroxysmal atrial fibrillation.
Article in Herzschrittmachertherapie & Elektrophysiologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- High-power-short-duration-radiofrequency-, cryoballoon-, and pulsed-field-ablation: a prospective clinical study.BMC cardiovascular disorders · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCatheter ablation for atrial fibrillation (AF) has become an effective treatment to control symptoms. The second generation cryoballoon (CB) was designed for more efficient and homogenous freeze. Radiofrequency (RF) ablation catheters using three-dimensional electroanatomical mapping with the use of contact-force radiofrequency (CF RF) technology has achieved good results in several studies.
objectivesTo compare the efficacy and safety of second-generation CB ablation in contrast to CF RF ablation in the ablation of paroxysmal AF.
methodsA total of 81 consecutive patients suffering from paroxysmal AF underwent pulmonary vein isolation (PVI) either by the second generation cryoballoon (n = 44) or a contact force-sensing RF catheter (n = 37). The study was conducted at Ain Shams University Hospitals and Royal Brompton & Harefield NHS trust. Baseline data, procedural data and patient follow up-at 3, 6 and 12 months-were collected and analysed.
resultsThe mean age was 53.8 ± 15 years in the CB group and 62.4 ± 12 years in the RF group, females representing 40.9% and 48.6% respectively. The baseline characteristics were comparable, but the CB group had less left atrial diameter and more left ventricular ejection fraction. The CB procedure was shorter (94.4 ± 39.3 vs. 140.8 ± 44.3 min, p < 0.0001), with longer fluoroscopy time (30 vs. 15.1 min, p = 0.047). Procedural complications were comparable between the two groups (CB 4.6%, CF RF 2.7%, p = 0.411). After 1 year, the recurrence rate in the CB group was similar to RF (27.3% vs. 27% respectively, p = 0.980).
conclusionSecond-generation CB ablation of paroxysmal AF has similar efficacy and safety to contact force-sensing RF catheters, with shorter procedure times and more fluoroscopy.